Inspection 344386974 OPENED OCT 16, 2019Closed
6839 Errick Rd, North Tonawanda, NY 14120 · Elementary and Secondary Schools · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
North Tonawanda, New York · Elementary and Secondary Schools · NAICS 611110
OSHA has inspected Niagara Wheatfield Central School District Errick Street Elementary School 2 times in New York since 2019.
The latest one began on Oct 16, 2019 to follow up on an earlier case, in North Tonawanda.
Those inspections ended with 6 citation items: 5 serious and 1 other-than-serious.
None of the citations carried a penalty.
Electrical equipment, general requirements comes up most often in these citations: 3 items under 1910.303.
How that compares: the median penalty per cited inspection for education employers since 2015 is $0, and Niagara Wheatfield Central School District Errick Street Elementary School averages $0 (1 cited inspection).
New York · latest 90 days of OSHA records
366employers cited
3 of them in the same industry
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch Niagara Wheatfield Central School District Errick Street Elementary School and get notified the morning OSHA posts a new citation for it.
Watch this company6839 Errick Rd, North Tonawanda, NY 14120 · Elementary and Secondary Schools · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
6839 Errick Rd, North Tonawanda, NY 14120 · Elementary and Secondary Schools · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.303(b)(7)(i) · Electrical equipment, general requirements |
Serious | $0 | $0 | Sep 20, 2019 | Final |
| Citation 1, item 2 29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements |
Serious | $0 | $0 | Sep 20, 2019 | Final |
| Citation 1, item 3 29 CFR 1910.303(f)(2) · Electrical equipment, general requirements |
Serious | $0 | $0 | Sep 20, 2019 | Final |
| Citation 1, item 4 29 CFR 1910.334(a)(2)(ii) · Using electrical equipment |
Serious | $0 | $0 | Sep 20, 2019 | Final |
| Citation 1, item 5 29 CFR 1910.334(a)(3)(ii) · Using electrical equipment |
Serious | $0 | $0 | Sep 20, 2019 | Final |
| Citation 2, item 1 29 CFR 12 NYCRR PART 801.32(A)(4) |
Other-than-serious | $0 | $0 | Sep 20, 2019 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.303(b)(7)(i)
(i) Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings shall be effectively closed to afford protection substantially equivalent to the wall of the equipment.
29 CFR 1910.303(b)(7)(iv)
(iv) There shall be no damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating.
29 CFR 1910.303(f)(2)
(2) Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.