OSHA SearchOSHA records by employer

Nick Falcone & Sons, Inc.: OSHA inspections and violations

Plymouth Meeting, Pennsylvania · Highway, Street, and Bridge Construction · NAICS 237310

3inspections
7citation items
$10,000current penalties
Oct 16, 2015last inspection

Nick Falcone & Sons, Inc. has 3 OSHA inspections on record in Pennsylvania, the first in 1994.

OSHA's last visit started on Oct 16, 2015 as part of a related case, in Bala Cynwyd.

Across those inspections OSHA issued 7 citation items: 6 serious and 1 other-than-serious.

OSHA proposed $12,800 in penalties. After settlements and reviews the total is $10,000, down 22%.

Most often, OSHA cited 1926.651, excavations (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Nick Falcone & Sons, Inc. averages $7,000 over 1 cited inspection in that time.

Nick Falcone & Sons, Inc.: OSHA citation items per year, 1994 to 2015
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

277employers cited

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Nick Falcone & Sons, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340996180 OPENED OCT 16, 2015Closed

Unprogrammed related · Partial · Safety · 5 employees at the site · Closed Jan 12, 2016

Righters Ferry Apartments 600 Righters Ferry Road, Bala Cynwyd, PA 19004 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(k)(1) · Excavations
Serious$4,900$3,500Dec 9, 2015Final
Citation 1, item 2
29 CFR 1926.652(a)(1) · Trench protection
Serious$4,900$3,500Dec 9, 2015Final

Inspection 307022285 OPENED NOV 17, 2004Closed

Referral · Partial · Safety · 35 employees at the site · Closed Dec 1, 2004

Columbus Ave. & Providence Rd., Edgemont, PA 19039 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 123263741 OPENED APR 18, 1994Closed

Referral · Complete · Safety · 5 employees at the site · Closed May 24, 1994

Chemical Road & Germantown Pike, Plymouth Meeting, PA 19462 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.652(a)(1) · Trench protection
Serious$1,500$1,500May 9, 1994Closed
Citation 1, item 2
29 CFR 1926.651(c)(2) · Excavations
Serious$600$600May 9, 1994Closed
Citation 1, item 3
29 CFR 1926.651(l)(1) · Excavations
Serious$450$450May 9, 1994Closed
Citation 1, item 4
29 CFR 1926.251(c)(4)(iii) · Rigging equipment for material handling
Serious$450$450May 9, 1994Closed
Citation 2, item 1
29 CFR 1926.21(b)(6)(i) · Construction safety training
Other-than-serious$0$0May 9, 1994Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.251 · Rigging equipment for material handling

29 CFR 1926.251(c)(4)(iii)

(iii) Eyes in wire rope bridles, slings, or bull wires shall not be formed by wire rope clips or knots.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.651(k)(1)

(k) Inspections. (1) Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.

29 CFR 1926.652 · Trench protection

Other highway, street, and bridge construction employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.