OSHA SearchOSHA records by employer

Niksic Air Conditioning and Heating LLC: OSHA inspections and violations

Saint Peters, Missouri · All Other Specialty Trade Contractors · NAICS 238990

1inspections
4citation items
$15,249current penalties
Oct 17, 2019last inspection

Niksic Air Conditioning and Heating LLC has one OSHA inspection on record in Missouri.

OSHA opened it on Oct 17, 2019, in Saint Peters.

From that inspection OSHA issued 4 citation items: 4 serious.

OSHA proposed $30,498 in penalties. After settlements and reviews the total is $15,249, down 50%.

Most often, OSHA cited 1926.651, excavations (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Niksic Air Conditioning and Heating LLC averages $15,249 over 1 cited inspection in that time.

Niksic Air Conditioning and Heating LLC: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Missouri · latest 90 days of OSHA records

124employers cited

Get notified the morning OSHA posts each new citation in Missouri: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Missouri

Checking a subcontractor, a client or your own company? Watch Niksic Air Conditioning and Heating LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344384458 OPENED OCT 17, 2019Closed

Unprogrammed other · Partial · Safety · 30 employees at the site · Closed Jul 21, 2020

50 Richmond Center Boulevard, Saint Peters, MO 63376 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Serious$9,282$4,641Jan 13, 2020Final
Citation 1, item 2
29 CFR 1926.651(j)(2) · Excavations
Serious$3,978$1,989Jan 13, 2020Final
Citation 1, item 3
29 CFR 1926.651(k)(1) · Excavations
Serious$7,956$3,978Jan 13, 2020Final
Citation 1, item 4
29 CFR 1926.652(a)(1) · Trench protection
Serious$9,282$4,641Jan 13, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.651(j)(2)

(2) Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.

29 CFR 1926.651(k)(1)

(k) Inspections. (1) Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.

29 CFR 1926.652 · Trench protection

Other all other specialty trade contractors employers in Missouri

Alert subscribers get notified of each newly cited employer in Missouri the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.