Noel Alvarado-Perez: OSHA inspections and violations

Terrell, Texas · Plumbing, Heating, and Air-Conditioning Contractors · NAICS 238220

1inspections
3citation items
$7,680current penalties
Jun 15, 2016last inspection

Noel Alvarado-Perez has one OSHA inspection on record in Texas.

OSHA opened it on Jun 15, 2016 after a fatality or catastrophe, in Terrell.

From that inspection OSHA issued 3 citation items: 3 serious.

OSHA proposed $15,143 in penalties. After settlements and reviews the total is $7,680, down 49%.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Noel Alvarado-Perez averages $7,680 over 1 cited inspection in that time.

1 inspection on this page followed a fatal incident.

Noel Alvarado-Perez: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

399employers cited

11 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Noel Alvarado-Perez and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341552669 OPENED JUN 15, 2016Closed

Fatality or catastrophe · Partial · Safety · 1 employee at the site · Closed Mar 6, 2024

307 West Moore Avenue, Terrell, TX 75160 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Incident on Jun 14, 2016 (fatal): Employee electrocuted while installing hvac equipment

At 11:50 a.m. on June 14, 2016 an employee and a co-worker were installing air conditioning equipment in an attic. Prior to the incident, the employee had installed plywood decking on the ceiling joists to serve as a base for installing the AC equipment in the attic crawl space of a building. The employee and the coworker had also placed two large components of the AC equipment in the attic. An electrical conduit terminating at a junction box was located inside the attic. The junction box, which provided power to a light bulb located in the middle of a back office area, contained a lock nut that was not installed on the strain relief coupling of the metal conduit. A sharp edge of the loose coupling came in contact with the wires, which resulted in compromised wires causing the junction box and metal conduit to become energized. Prior to entering the attic, the power to the electrical conduit running through the attic crawl space had not been turned off. As the employee and coworker entered the space to install the AC equipment, the employee was electrocuted when he came into contact with the energized conduit. conduit.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$12,471$6,240Nov 9, 2016Final
Citation 1, item 1b
29 CFR 1926.1203(a) · Confined Spaces in Construction: general requirements
Serious$0$0Nov 9, 2016Final
Citation 1, item 2
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$2,672$1,440Nov 9, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1203 · Confined Spaces in Construction: general requirements

29 CFR 1926.1203(a)

(a) Before it begins work at a worksite, each employer must ensure that a competent person identifies all confined spaces in which one or more of the employees it directs may work, and identifies each space that is a permit space, through consideration and evaluation of the elements of that space, including testing as necessary.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.416(a)(1)

(a) Protection of employees. (1) No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(4)(i)

(4) Holes. (i) Each employee on walking/working surfaces shall be protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes.

Other plumbing, heating, and air-conditioning contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.