OSHA SearchOSHA records by employer

Norberto Terrazas: OSHA inspections and violations

Converse, Texas · Masonry Contractors · NAICS 238140

1inspections
3citation items
$3,108current penalties
Dec 8, 2022last inspection

OSHA inspectors have visited Norberto Terrazas in Texas one time.

It opened on Dec 8, 2022 as a planned inspection, in Converse.

In all, OSHA issued 3 citation items: 3 serious.

The proposed penalties came to $6,216; today they stand at $3,108, 50% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Norberto Terrazas averages $3,108 across 1 cited inspection.

Norberto Terrazas: OSHA citation items per year, 2022 to 2022
Citation items per year, by inspection date.

Want to know if OSHA cites Norberto Terrazas again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 346380983 OPENED DEC 8, 2022Closed

Planned · Partial · Safety · 2 employees at the site · Closed Jan 27, 2025

3515 Sandcastle Way, Converse, TX 78109 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$1,865$932Jan 12, 2023Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,865$932Jan 12, 2023Final
Citation 1, item 3
29 CFR 1926.451(e)(4)(i) · Scaffolds, general requirements
Serious$2,486$1,243Jan 12, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(e)(4)(i)

(i) A stairrail consisting of a toprail and a midrail shall be provided on each side of each scaffold stairway.