OSHA SearchOSHA records by employer

Normand Berube Builders Inc.: OSHA inspections and violations

South Portland, Maine · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

4inspections
24citation items
$7,970current penalties
Dec 20, 2017last inspection

Normand Berube Builders Inc. has 4 OSHA inspections on record in Maine, the first in 1985.

OSHA's last visit started on Dec 20, 2017 after a complaint, in Gorham.

Across those inspections OSHA issued 24 citation items: 11 serious, 3 repeat and 10 other-than-serious.

OSHA proposed $12,859 in penalties. After settlements and reviews the total is $7,970, down 38%.

Most often, OSHA cited 1926.500, scope, application, and definitions applicable to this subpart (7 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Normand Berube Builders Inc. averages $4,890 over 1 cited inspection in that time.

Normand Berube Builders Inc.: OSHA citation items per year, 1985 to 2017
Citation items per year, by inspection date.

Maine · latest 90 days of OSHA records

34employers cited

Get notified the morning OSHA posts each new citation in Maine: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maine

Checking a subcontractor, a client or your own company? Watch Normand Berube Builders Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342843778 OPENED DEC 20, 2017Closed

Complaint · Partial · Safety · 3 employees at the site · Closed Jan 29, 2018

Shires Meadow Drive, Gorham, ME 04038 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$3,803$1,902Jan 2, 2018Final
Citation 1, item 2
29 CFR 1926.501(b)(14) · Fall protection in construction
Serious$3,803$1,902Jan 2, 2018Final
Citation 1, item 3
29 CFR 1926.1052(c)(1)(i) · Stairways in construction
Serious$2,173$1,086Jan 2, 2018Final

Inspection 18059295 OPENED NOV 8, 1990Closed

Unprogrammed related · Complete · Safety · 5 employees at the site · Closed Oct 10, 1991

5 Wade Street, Augusta, ME 04330 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.450(a)(9) · Scope, application and definitions applicable to this subpart
Serious$200$200Nov 27, 1990Closed
Citation 1, item 2
29 CFR 1926.451(u)(3) · Scaffolds, general requirements
Serious$300$300Nov 27, 1990Closed
Citation 1, item 3
29 CFR 1926.500(b)(5) · Scope, application, and definitions applicable to this subpart
Serious$200$200Nov 27, 1990Closed
Citation 1, item 4
29 CFR 1926.500(b)(7) · Scope, application, and definitions applicable to this subpart
Serious$200$200Nov 27, 1990Closed
Citation 2, item 1
29 CFR 1926.59(e)(1) · Hazard communication
Other-than-serious$0$0Nov 27, 1990Closed
Citation 2, item 2
29 CFR 1926.59(g)(8) · Hazard communication
Other-than-serious$0$0Nov 27, 1990Closed
Citation 2, item 3
29 CFR 1926.59(h) · Hazard communication
Other-than-serious$0$0Nov 27, 1990Closed

Inspection 101407880 OPENED SEP 22, 1987Closed

Planned · Complete · Safety · 5 employees at the site · Closed Jan 11, 1988

Gallagher Farms, Westbrook St., S. Portland, ME 04106 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.500(d)(1) · Scope, application, and definitions applicable to this subpart
Serious$120$120Oct 7, 1987Closed
Citation 2, item 1
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Repeat$810$810Oct 7, 1987Closed
Citation 2, item 2
29 CFR 1926.450(a)(10) · Scope, application and definitions applicable to this subpart
Repeat$420$420Oct 7, 1987Closed
Citation 2, item 3
29 CFR 1926.500(c)(1) · Scope, application, and definitions applicable to this subpart
Repeat$560$560Oct 7, 1987Closed

Inspection 908772 OPENED NOV 25, 1985Closed

Referral · Complete · Safety · 12 employees at the site · Closed Jan 24, 1986

696 Westbrook Street, South Portland, ME 04106 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$90$90Dec 9, 1985Closed
Citation 1, item 2
29 CFR 1926.500(b)(1) · Scope, application, and definitions applicable to this subpart
Serious$90$90Dec 9, 1985Closed
Citation 1, item 3
29 CFR 1926.500(c)(1) · Scope, application, and definitions applicable to this subpart
Serious$90$90Dec 9, 1985Closed
Citation 2, item 1
29 CFR 1926.300(a) · Tools—Hand and Power: general requirements
Other-than-serious$0$0Dec 9, 1985Closed
Citation 2, item 2
29 CFR 1926.400(a) · Introduction
Other-than-serious$0$0Dec 9, 1985Closed
Citation 2, item 3
29 CFR 1926.401(a)(1) · [Reserved]
Other-than-serious$0$0Dec 9, 1985Closed
Citation 2, item 4
29 CFR 1926.401(j)(3) · [Reserved]
Other-than-serious$0$0Dec 9, 1985Closed
Citation 2, item 5
29 CFR 1926.401(a)(8) · [Reserved]
Other-than-serious$0$0Dec 9, 1985Closed
Citation 2, item 6
29 CFR 1926.450(a)(10) · Scope, application and definitions applicable to this subpart
Other-than-serious$0$0Dec 9, 1985Closed
Citation 2, item 7
29 CFR 1926.500(c)(2) · Scope, application, and definitions applicable to this subpart
Other-than-serious$0$0Dec 9, 1985Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(a)(1)

(a) Machine guarding—(1) Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are—barrier guards, two-hand tripping devices, electronic safety devices, etc.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)(i)

(i) At least one handrail; and

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.300(a)

(a) Condition of tools. All hand and power tools and similar equipment, whether furnished by the employer or the employee, shall be maintained in a safe condition.

29 CFR 1926.400 · Introduction

29 CFR 1926.401 · [Reserved]

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.450 · Scope, application and definitions applicable to this subpart

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.500 · Scope, application, and definitions applicable to this subpart

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.59 · Hazard communication

Other new single-family housing construction (except for-sale builders) employers in Maine

Alert subscribers get notified of each newly cited employer in Maine the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.