Inspection 340882729 OPENED AUG 28, 2015Closed
733 Broadway, Albany, NY 12201 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Norstar Building Corporation has 7 OSHA inspections on record in New York, the first in 2001.
OSHA's last visit started on Aug 28, 2015 as a planned inspection, in Albany.
Across those inspections OSHA issued 5 citation items: 3 serious and 2 other-than-serious.
OSHA proposed $4,382 in penalties. After settlements and reviews the total is $2,665, down 39%.
Most often, OSHA cited 1926.405, job-site wiring (3 items).
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Norstar Building Corporation averages $2,400 over 1 cited inspection in that time.
New York · latest 90 days of OSHA records
360employers cited
13 of them in the same industry
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch Norstar Building Corporation and get notified the morning OSHA posts a new citation for it.
Watch this companyOSHA records show Norstar Building Corporation at 5 sites in 2 states. Together they've had 10 inspections and $2,665 in current penalties.
We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.
Included with any plan: the site-by-site record for all 5 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.
See plans733 Broadway, Albany, NY 12201 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
733 Broadway, Albany, NY 12207 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.403(b)(2) · Electrical equipment on job sites |
Other-than-serious | $2,800 | $1,680 | Aug 24, 2015 | Final |
| Citation 1, item 1b 29 CFR 1926.405(a)(2)(ii)(f) · Job-site wiring |
Other-than-serious | $0 | $0 | Aug 24, 2015 | Final |
| Citation 1, item 4a 29 CFR 1926.405(j)(1)(i) · Job-site wiring |
Serious | $1,200 | $720 | Aug 24, 2015 | Final |
| Citation 1, item 4b 29 CFR 1926.405(b)(2) · Job-site wiring |
Serious | $0 | $0 | Aug 24, 2015 | Final |
Starwood Apartments, 845 Starbuck Ave., Watertown, NY 13601 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
73 Second Street, Albany, NY 12201 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Creighton Storey Homes, Thrid Ave., Albany, NY 12201 · Residential Remodelers · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Frederick Douglas Towers-building 210, Buffalo, NY 14204 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Frederick Douglas Towers-building 210, Buffalo, NY 14204 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.1052(c)(1) · Stairways in construction |
Serious | $382 | $265 | Jul 13, 2001 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.1052(c)(1)
(1) Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with:
29 CFR 1926.403(b)(2)
(2) Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.
29 CFR 1926.405(a)(2)(ii)(f)
(F) Temporary lights shall not be suspended by their electric cords unless cords and lights are designed for this means of suspension.