OSHA SearchOSHA records by employer

North Jersey Construction Management LLC: OSHA inspections and violations

Paterson, New Jersey · New Multifamily Housing Construction (except For-Sale Builders) · NAICS 236116

4inspections
11citation items
$32,375current penalties
Aug 15, 2019last inspection

Since 2015, OSHA inspectors have visited North Jersey Construction Management LLC in New Jersey 4 times.

The most recent inspection opened on Aug 15, 2019 as a planned inspection, in Paterson.

In all, OSHA issued 11 citation items: 10 serious and 1 repeat.

The proposed penalties came to $37,015; today they stand at $32,375, 13% less.

The rule cited most here is 1926.1052 (stairways in construction), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. North Jersey Construction Management LLC averages $8,094 across 4 cited inspections.

North Jersey Construction Management LLC: OSHA citation items per year, 2015 to 2019
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

276employers cited

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch North Jersey Construction Management LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344307988 OPENED AUG 15, 2019Closed

Planned · Partial · Safety · 5 employees at the site · Closed Apr 17, 2023

1 Courtland, Paterson, NJ 07503 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(f)(6) · Scaffolds, general requirements
Serious$4,376$4,376Dec 3, 2019Final

Inspection 344241385 OPENED FEB 22, 2019Closed

Planned · Partial · Safety · 3 employees at the site · Closed Apr 2, 2024

1 Court St, Paterson, NJ 07503 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.405(a)(2)(ii)(e) · Job-site wiring
Serious$3,751$3,751Aug 19, 2019Final
Citation 1, item 1b
29 CFR 1926.405(a)(2)(ii)(f) · Job-site wiring
Serious$0$0Aug 19, 2019Final
Citation 2, item 1
29 CFR 1926.1052(b)(1) · Stairways in construction
Repeat$8,752$8,752Aug 19, 2019Final

Inspection 343441242 OPENED JUN 1, 2018Closed

Planned · Partial · Safety · 3 employees at the site · Closed Oct 31, 2022

1089 Main St, Paterson, NJ 07503 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.56(a) · Illumination
Serious$4,268$4,268Sep 18, 2018Final
Citation 1, item 2
29 CFR 1926.1052(b)(1) · Stairways in construction
Serious$4,268$4,268Sep 18, 2018Final

Inspection 340883487 OPENED AUG 29, 2015Closed

Planned · Partial · Safety · 12 employees at the site · Closed Sep 21, 2016

55-57 Courtland St, Paterson, NJ 07503 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.95(a) · Criteria for personal protective equipment
Serious$1,600$960Jan 15, 2016Final
Citation 1, item 2
29 CFR 1926.252(a) · Disposal of waste materials
Serious$2,800$1,680Jan 15, 2016Final
Citation 1, item 3
29 CFR 1926.403(i)(2)(i) · Electrical equipment on job sites
Serious$1,600$960Jan 15, 2016Final
Citation 1, item 4
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,800$1,680Jan 15, 2016Final
Citation 1, item 5
29 CFR 1926.1052(c)(1) · Stairways in construction
Serious$2,800$1,680Jan 15, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(b)(1)

(1) Except during stairway construction, foot traffic is prohibited on stairways with pan stairs where the treads and/or landings are to be filled in with concrete or other material at a later date, unless the stairs are temporarily fitted with wood or other solid material at least to the top edge of each pan. Such temporary treads and landings shall be replaced when worn below the level of the top edge of the pan.

29 CFR 1926.1052(c)(1)

(1) Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with:

29 CFR 1926.252 · Disposal of waste materials

29 CFR 1926.252(a)

(a) Whenever materials are dropped more than 20 feet to any point lying outside the exterior walls of the building, an enclosed chute of wood, or equivalent material, shall be used. For the purpose of this paragraph, an enclosed chute is a slide, closed in on all sides, through which material is moved from a high place to a lower one.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.56 · Illumination

29 CFR 1926.95 · Criteria for personal protective equipment

Other new multifamily housing construction (except for-sale builders) employers in New Jersey

Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.