OSHA SearchOSHA records by employer

Northland Exteriors Co: OSHA inspections and violations

Burnsville, Minnesota · Roofing Contractors · NAICS 238160

5inspections
14citation items
$10,725current penalties
Sep 1, 2022last inspection

Northland Exteriors Co has 5 OSHA inspections on record in Minnesota, the first in 2012.

OSHA's last visit started on Sep 1, 2022 after a complaint, in Sauk Rapids.

Across those inspections OSHA issued 14 citation items: 14 serious.

OSHA proposed $12,575 in penalties. After settlements and reviews the total is $10,725, down 15%.

Most often, OSHA cited 1926.501, fall protection in construction (7 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Northland Exteriors Co averages $2,231 over 4 cited inspections in that time.

Northland Exteriors Co: OSHA citation items per year, 2012 to 2022
Citation items per year, by inspection date.

Minnesota · latest 90 days of OSHA records

370employers cited

36 of them in the same industry

Get notified the morning OSHA posts each new citation in Minnesota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Minnesota

Checking a subcontractor, a client or your own company? Watch Northland Exteriors Co and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346200769 OPENED SEP 1, 2022Closed

Complaint · Partial · Safety · 8 employees at the site · Closed Oct 24, 2023

122 Benton Oaks Dr, Sauk Rapids, MN 56379 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 182.653(08)
Serious$250$250Feb 24, 2023Final
Citation 1, item 2
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$1,750$1,750Feb 24, 2023Final
Citation 1, item 3
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$375$375Feb 24, 2023Final

Inspection 345428585 OPENED JUL 14, 2021Closed

Complaint · Partial · Safety · 6 employees at the site · Closed Nov 5, 2021

119 Mill Pond St, Motley, MN 56466 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 182.653(08)
Serious$350$350Aug 10, 2021Final
Citation 1, item 2a
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$2,450$2,450Aug 10, 2021Final
Citation 1, item 2b
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$0$0Aug 10, 2021Final
Citation 1, item 3
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$2,450$2,450Aug 10, 2021Final

Inspection 342985041 OPENED FEB 27, 2018Closed

Planned · Complete · Safety · 4 employees at the site · Closed Apr 10, 2019

1066 County Hwy 10, Minneapolis, MN 55432 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 182.653(08)
Serious$250$150Mar 14, 2018Final
Citation 1, item 2a
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,375$850Mar 14, 2018Final
Citation 1, item 2b
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$0$0Mar 14, 2018Final

Inspection 341918167 OPENED NOV 9, 2016Closed

Planned · Complete · Safety · 2 employees at the site · Closed Jan 30, 2017

123 6th Ave Se, Rochester, MN 55904 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.304(i) · Woodworking tools
Serious$525$300Nov 21, 2016Final

Inspection 316755131 OPENED OCT 16, 2012Closed

Planned · Partial · Safety · 7 employees at the site · Closed Feb 12, 2013

14165 Portland Ave, Burnsville, MN 55337 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$350$200Nov 5, 2012Final
Citation 1, item 2a
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$2,450$1,600Nov 5, 2012Final
Citation 1, item 2b
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$0$0Nov 5, 2012Contested

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1820.6530

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.304 · Woodworking tools

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(1)

(b)(1) Unprotected sides and edges. Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.

29 CFR 1926.501(b)(11)

(11) Steep roofs. Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems.

29 CFR 1926.503 · Fall protection training in construction

Other roofing contractors employers in Minnesota

Alert subscribers get notified of each newly cited employer in Minnesota the morning it is posted. See the alert plans.