OSHA SearchOSHA records by employer

Northside Masonry: OSHA inspections and violations

Flower Mound, Texas · Masonry Contractors · NAICS 238140

1inspections
3citation items
$3,000current penalties
Nov 16, 2022last inspection

Northside Masonry has one OSHA inspection on record in Texas.

OSHA opened it on Nov 16, 2022 as a planned inspection, in Flower Mound.

From that inspection OSHA issued 3 citation items: 3 serious.

OSHA proposed $5,128 in penalties. After settlements and reviews the total is $3,000, down 41%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,079. Northside Masonry averages $3,000 over 1 cited inspection in that time.

Northside Masonry: OSHA citation items per year, 2022 to 2022
Citation items per year, by inspection date.

Want to know if OSHA cites Northside Masonry again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 346363385 OPENED NOV 16, 2022Closed

Planned · Partial · Safety · 6 employees at the site · Closed Feb 17, 2023

1500 Long Prairie Rd., Flower Mound, TX 75028 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,642$1,519Nov 18, 2022Final
Citation 1, item 2a
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$2,486$1,481Nov 18, 2022Final
Citation 1, item 2b
29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements
Serious$0$0Nov 18, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.451(h)(2)(ii)

(ii) A toeboard shall be erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below, except on float (ship) scaffolds where an edging of 3/4 × 1 1/2 inch (2 × 4 cm) wood or equivalent may be used in lieu of toeboards;

Other masonry contractors employers in Texas

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.