Inspection 342247897 OPENED APR 13, 2017Closed
135 S 7th Street, Tooele, UT 84074 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
OSHA has inspected Northwest Welding & Mechanical Inc 3 times in Utah since 2016.
The latest one began on Apr 13, 2017 after an accident, in Tooele.
Those inspections ended with 5 citation items: 5 serious.
Penalties were first proposed at $3,450 and now stand at $2,550, 26% lower after settlements or reviews.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Northwest Welding & Mechanical Inc averages $1,275 (2 cited inspections).
Utah · latest 90 days of OSHA records
73employers cited
Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Utah
Checking a subcontractor, a client or your own company? Watch Northwest Welding & Mechanical Inc and get notified the morning OSHA posts a new citation for it.
Watch this company135 S 7th Street, Tooele, UT 84074 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
5175 W 4000 S, Hooper, UT 84315 · Other Foundation, Structure, and Building Exterior Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.106(d)(6)(iii) · Flammable liquids |
Serious | $800 | $800 | Apr 20, 2017 | Final |
| Citation 1, item 2 29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods |
Serious | $850 | $850 | Apr 20, 2017 | Final |
5175 W 4000 S, Hooper, UT 84315 · Other Foundation, Structure, and Building Exterior Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes |
Serious | $600 | $300 | Dec 2, 2016 | Final |
| Citation 1, item 2 29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting |
Serious | $600 | $300 | Dec 2, 2016 | Final |
| Citation 1, item 3 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Serious | $600 | $300 | Dec 2, 2016 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.106(d)(6)(iii)
(iii) Spill containment. The storage area shall be graded in a manner to divert possible spills away from buildings or other exposures or shall be surrounded by a curb at least 6 inches high. When curbs are used, provisions shall be made for draining of accumulations of ground or rain water or spills of flammable liquids. Drains shall terminate at a safe location and shall be accessible to operation under fire conditions.
29 CFR 1910.253(b)(4)(iii)
(iii) Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.
29 CFR 1910.303(b)(2)
(2) Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.
Alert subscribers get notified of each newly cited employer in Utah the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.