OSHA SearchOSHA records by employer

NP Sunset LLC: OSHA inspections and violations

Henderson, Nevada · Casino Hotels · NAICS 721120

1inspections
6citation items
$9,230current penalties
Jan 4, 2024last inspection

OSHA inspectors have visited NP Sunset LLC in Nevada one time.

It opened on Jan 4, 2024 as a planned inspection, in Henderson.

In all, OSHA issued 6 citation items: 3 serious and 3 other-than-serious.

The proposed penalties came to $18,461; today they stand at $9,230, 50% less.

Among hotel and restaurant employers, the typical cited inspection since 2015 ends with a $1,350 penalty. NP Sunset LLC averages $9,230 across 1 cited inspection.

NP Sunset LLC: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Nevada · latest 90 days of OSHA records

115employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Nevada: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Nevada

Checking a subcontractor, a client or your own company? Watch NP Sunset LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347194383 OPENED JAN 4, 2024Closed

Planned · Complete · Safety · 700 employees at the site · Closed Apr 3, 2024

1301 West Sunset Road, Henderson, NV 89014 · Casino Hotels · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR NEVADA REVISED STATUTE 618.375(1)
Serious$7,590$3,795Mar 6, 2024Final
Citation 1, item 2
29 CFR 1910.28(b)(3)(ii) · Fall protection in general industry
Serious$5,876$2,938Mar 6, 2024Final
Citation 1, item 3
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$4,995$2,498Mar 6, 2024Final
Citation 2, item 1
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Mar 6, 2024Final
Citation 2, item 2
29 CFR 1910.303(g)(1)(i)(a) · Electrical equipment, general requirements
Other-than-serious$0$0Mar 6, 2024Final
Citation 2, item 3
29 CFR 1910.1030(h)(2)(ii) · Bloodborne pathogens
Other-than-serious$0$0Mar 6, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1030 · Bloodborne pathogens

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(c)(1)

(c) General requirements. (1) The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury.

29 CFR 1910.28 · Fall protection in general industry

29 CFR 1910.28(b)(3)(ii)

(ii) Each employee is protected from tripping into or stepping into or through any hole that is less than 4 feet (1.2 m) above a lower level by covers or guardrail systems.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(g)(1)(i)(a)

(A) The depth of the working space in the direction of access to live parts may not be less than indicated in Table S-1. Distances shall be measured from the live parts if they are exposed or from the enclosure front or opening if they are enclosed;

29 CFR 1910.305 · Electrical wiring methods

Other casino hotels employers in Nevada

Alert subscribers get notified of each newly cited employer in Nevada the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.