OSHA SearchOSHA records by employer

NW Electric, Inc.: OSHA inspections and violations

Bethel, Alaska · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

1inspections
3citation items
$1,800current penalties
Oct 25, 2016last inspection

OSHA has inspected NW Electric, Inc. once in Alaska.

The inspection began on Oct 25, 2016 after a complaint, in Bethel.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $1,800 and still stand at $1,800.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and NW Electric, Inc. averages $1,800 (1 cited inspection).

NW Electric, Inc.: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Alaska · latest 90 days of OSHA records

37employers cited

Get notified the morning OSHA posts each new citation in Alaska: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Alaska

Checking a subcontractor, a client or your own company? Watch NW Electric, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341872950 OPENED OCT 25, 2016Closed

Complaint · Partial · Safety · 3 employees at the site · Closed Apr 17, 2017

131 Akakeek St., Bethel, AK 99559 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$600$600Mar 2, 2017Final
Citation 1, item 2
29 CFR 1926.405(j)(1)(i) · Job-site wiring
Serious$600$600Mar 2, 2017Final
Citation 1, item 3
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$600$600Mar 2, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(j)(1)(i)

(j) Equipment for general use—(1) Lighting fixtures, lampholders, lamps, and receptacles—(i) Live parts. Fixtures, lampholders, lamps, rosettes, and receptacles shall have no live parts normally exposed to employee contact. However, rosettes and cleat-type lampholders and receptacles located at least 8 feet (2.44 m) above the floor may have exposed parts.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(1)

(b)(1) Unprotected sides and edges. Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.

Other electrical contractors and other wiring installation contractors employers in Alaska

Alert subscribers get notified of each newly cited employer in Alaska the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.