Inspection 346486855 OPENED FEB 7, 2023Closed
207 Bushwick Avenue, Brooklyn, NY 11206 · Elementary and Secondary Schools · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Nycdoe PS 196 has 3 OSHA inspections on record in New York, the first in 2013.
OSHA's last visit started on Feb 7, 2023 to follow up on an earlier case, in Brooklyn.
Across those inspections OSHA issued 4 citation items: 3 serious and 1 other-than-serious.
OSHA did not attach a penalty to any of these citations.
Most often, OSHA cited 1926.451, scaffolds, general requirements (2 items).
For context, across all education employers the median penalty per cited inspection since 2015 is $0. Nycdoe PS 196 averages $0 over 1 cited inspection in that time.
New York · latest 90 days of OSHA records
350employers cited
3 of them in the same industry
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch Nycdoe PS 196 and get notified the morning OSHA posts a new citation for it.
Watch this company207 Bushwick Avenue, Brooklyn, NY 11206 · Elementary and Secondary Schools · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
207 Bushwick Avenue, Brooklyn, NY 11206 · Elementary and Secondary Schools · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(c)(1)(ii) · Scaffolds, general requirements |
Serious | $0 | $0 | Sep 9, 2022 | Final |
| Citation 1, item 2 29 CFR 1926.451(f)(7) · Scaffolds, general requirements |
Serious | $0 | $0 | Sep 9, 2022 | Final |
| Citation 1, item 3 29 CFR 1926.454(a) · Scaffold training |
Serious | $0 | $0 | Sep 9, 2022 | Final |
| Citation 2, item 1 29 CFR 12 NYCRR PART 801.40(A) |
Other-than-serious | $0 | $0 | Sep 9, 2022 | Final |
7125 113 Street, Forest Hill, Queens, NY 11375 · Elementary and Secondary Schools · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.451(c)(1)(ii)
(ii) Guys, ties, and braces shall be installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and be repeated vertically at locations of horizontal members every 20 feet (6.1 m) or less thereafter for scaffolds 3 feet (0.91 m) wide or less, and every 26 feet (7.9 m) or less thereafter for scaffolds greater than 3 feet (0.91 m) wide. The top guy, tie or brace of completed scaffolds shall be placed no further than the 4:1 height from the top. Such guys, ties and braces shall be installed at each end of the scaffold and at horizontal intervals not to exceed 30 feet (9.1 m) (measured from one end [not both] towards the other).
29 CFR 1926.451(f)(7)
(7) Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person.
29 CFR 1926.454(a)
(a) The employer shall have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. The training shall include the following areas, as applicable:
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.