Inspection 343007209 OPENED MAR 12, 2018Closed
1 Schodack Island Way, Schodack Landing, NY 12156 · Administration of Education Programs · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Schodack Landing, New York · Administration of Education Programs · NAICS 923110
OSHA has inspected Nysoprhp Schodack Island State Park 3 times in New York since 2008.
The latest one began on Mar 12, 2018 to follow up on an earlier case, in Schodack Landing.
Those inspections ended with 6 citation items: 6 serious.
None of the citations carried a penalty.
Electrical wiring methods comes up most often in these citations: 2 items under 1910.305.
How that compares: the median penalty per cited inspection for public administration employers since 2015 is $0, and Nysoprhp Schodack Island State Park averages $0 (1 cited inspection).
New York · latest 90 days of OSHA records
366employers cited
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch Nysoprhp Schodack Island State Park and get notified the morning OSHA posts a new citation for it.
Watch this company1 Schodack Island Way, Schodack Landing, NY 12156 · Administration of Education Programs · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1 Schodack Island Way, Schodack Landing, NY 12156 · Administration of Education Programs · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.37(b)(2) · Exit routes |
Serious | $0 | $0 | Feb 7, 2018 | Final |
| Citation 1, item 2 29 CFR 1910.151(c) · First aid and eyewash |
Serious | $0 | $0 | Feb 7, 2018 | Final |
| Citation 1, item 3 29 CFR 1910.215(a)(4) · Grinders and abrasive wheels |
Serious | $0 | $0 | Feb 7, 2018 | Final |
| Citation 1, item 4 29 CFR 1910.303(f)(2) · Electrical equipment, general requirements |
Serious | $0 | $0 | Feb 7, 2018 | Final |
| Citation 1, item 5 29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods |
Serious | $0 | $0 | Feb 7, 2018 | Final |
| Citation 1, item 6 29 CFR 1910.305(j)(2)(vi) · Electrical wiring methods |
Serious | $0 | $0 | Feb 7, 2018 | Final |
1 Schodack Way, Schodack Landing, NY 12156 · Nature Parks and Other Similar Institutions · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.151(c)
(c) Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use.
29 CFR 1910.215(a)(4)
(4) Work rests. On offhand grinding machines, work rests shall be used to support the work. They shall be of rigid construction and designed to be adjustable to compensate for wheel wear. Work rests shall be kept adjusted closely to the wheel with a maximum opening of one-eighth inch to prevent the work from being jammed between the wheel and the rest, which may cause wheel breakage. The work rest shall be securely clamped after each adjustment. The adjustment shall not be made with the wheel in motion.
29 CFR 1910.303(f)(2)
(2) Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.