Inspection 344284534 OPENED AUG 28, 2019Closed
201 Middle Rd, Horseheads, NY 14845 · Golf Courses and Country Clubs · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Horseheads, New York · Golf Courses and Country Clubs · NAICS 713910
NYSPRHP-Mark Twain State Park has 6 OSHA inspections on record in New York, the first in 2018.
OSHA's last visit started on Aug 28, 2019 to follow up on an earlier case, in Horseheads.
Across those inspections OSHA issued 24 citation items: 19 serious and 5 other-than-serious.
OSHA did not attach a penalty to any of these citations.
Most often, OSHA cited 1910.303, electrical equipment, general requirements (5 items).
For context, across all arts and recreation employers the median penalty per cited inspection since 2015 is $1,400. NYSPRHP-Mark Twain State Park averages $0 over 2 cited inspections in that time.
New York · latest 90 days of OSHA records
360employers cited
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch NYSPRHP-Mark Twain State Park and get notified the morning OSHA posts a new citation for it.
Watch this company201 Middle Rd, Horseheads, NY 14845 · Golf Courses and Country Clubs · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
201 Middle Rd, Horseheads, NY 14845 · Golf Courses and Country Clubs · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
201 Middle Rd, Horseheads, NY 14845 · Golf Courses and Country Clubs · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
201 Middle Rd, Horseheads, NY 14845 · Golf Courses and Country Clubs · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
201 Middle Rd, Horseheads, NY 14845 · Golf Courses and Country Clubs · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.23(a)(8) · Ladders in general industry |
Serious | $0 | $0 | Feb 13, 2019 | Final |
| Citation 1, item 2 29 CFR 1910.37(a)(3) · Exit routes |
Serious | $0 | $0 | Feb 13, 2019 | Final |
| Citation 1, item 3 29 CFR 1910.37(a)(4) · Exit routes |
Serious | $0 | $0 | Feb 13, 2019 | Final |
| Citation 1, item 4 29 CFR 1910.106(g)(3)(iii) · Flammable liquids |
Serious | $0 | $0 | Feb 13, 2019 | Final |
| Citation 1, item 5 29 CFR 1910.147(c)(1) · Lockout/tagout |
Serious | $0 | $0 | Feb 13, 2019 | Final |
| Citation 1, item 6 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Serious | $0 | $0 | Feb 13, 2019 | Final |
| Citation 1, item 7 29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts |
Serious | $0 | $0 | Feb 13, 2019 | Final |
| Citation 1, item 8 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Serious | $0 | $0 | Feb 13, 2019 | Final |
| Citation 1, item 9 29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements |
Serious | $0 | $0 | Feb 13, 2019 | Final |
| Citation 1, item 10 29 CFR 1910.303(b)(8)(i) · Electrical equipment, general requirements |
Serious | $0 | $0 | Feb 13, 2019 | Final |
| Citation 1, item 11 29 CFR 1910.303(f)(2) · Electrical equipment, general requirements |
Serious | $0 | $0 | Feb 13, 2019 | Final |
| Citation 1, item 12 29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements |
Serious | $0 | $0 | Feb 13, 2019 | Final |
| Citation 1, item 13 29 CFR 1910.305(j)(1)(i) · Electrical wiring methods |
Serious | $0 | $0 | Feb 13, 2019 | Final |
| Citation 1, item 14 29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods |
Serious | $0 | $0 | Feb 13, 2019 | Final |
| Citation 2, item 1 29 CFR 12 NYCRR PART 800.6(E) |
Other-than-serious | $0 | $0 | Feb 13, 2019 | Final |
| Citation 2, item 2 29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements |
Other-than-serious | $0 | $0 | Feb 13, 2019 | Final |
201 Middle Rd, Horseheads, NY 14845 · Golf Courses and Country Clubs · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.134(c)(1) · Respiratory protection |
Serious | $0 | $0 | Feb 13, 2019 | Final |
| Citation 1, item 2 29 CFR 1910.134(e)(1) · Respiratory protection |
Serious | $0 | $0 | Feb 13, 2019 | Final |
| Citation 1, item 3 29 CFR 1910.134(f)(1) · Respiratory protection |
Serious | $0 | $0 | Feb 13, 2019 | Final |
| Citation 1, item 4 29 CFR 1910.134(k)(1) · Respiratory protection |
Serious | $0 | $0 | Feb 13, 2019 | Final |
| Citation 1, item 5 29 CFR 1910.146(c)(3) · Permit-required confined spaces |
Serious | $0 | $0 | Feb 13, 2019 | Final |
| Citation 2, item 1 29 CFR 12 NYCRR PART 801.33(A) |
Other-than-serious | $0 | $0 | Feb 13, 2019 | Final |
| Citation 3, item 1 29 CFR 1910.1200(e)(1)(i) · Hazard communication |
Other-than-serious | $0 | $0 | Feb 13, 2019 | Final |
| Citation 3, item 2 29 CFR 1910.1200(g)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Feb 13, 2019 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.106(g)(3)(iii)
(iii) Emergency power cutoff. A clearly identified and easily accessible switch(es) or a circuit breaker(s) shall be provided at a location remote from dispensing devices, including remote pumping systems, to shut off the power to all dispensing devices in the event of an emergency.
29 CFR 1910.1200(e)(1)(i)
(i) A list of the hazardous chemicals known to be present using a product identifier that is referenced on the appropriate safety data sheet (the list may be compiled for the workplace as a whole or for individual work areas); and,
29 CFR 1910.1200(g)(1)
(g) Safety data sheets. (1) Chemical manufacturers and importers shall obtain or develop a safety data sheet for each hazardous chemical they produce or import. Employers shall have a safety data sheet in the workplace for each hazardous chemical which they use.
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.