Inspection 343070058 OPENED APR 4, 2018Closed
6820 Thompson Rd Po Box 4754, Syracuse, NY 13221 · Other Technical and Trade Schools · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
OSHA has inspected Ocm Boces Henry CT Building 2 times in New York since 2018.
The latest one began on Apr 4, 2018 to follow up on an earlier case, in Syracuse.
Those inspections ended with 9 citation items: 7 serious and 2 other-than-serious.
None of the citations carried a penalty.
Electrical wiring methods comes up most often in these citations: 3 items under 1910.305.
How that compares: the median penalty per cited inspection for education employers since 2015 is $0, and Ocm Boces Henry CT Building averages $0 (1 cited inspection).
New York · latest 90 days of OSHA records
361employers cited
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch Ocm Boces Henry CT Building and get notified the morning OSHA posts a new citation for it.
Watch this company6820 Thompson Rd Po Box 4754, Syracuse, NY 13221 · Other Technical and Trade Schools · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
6820 Thompson Rd Po Box 4754, Syracuse, NY 13221 · Other Technical and Trade Schools · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.151(c) · First aid and eyewash |
Serious | $0 | $0 | Feb 28, 2018 | Final |
| Citation 1, item 2 29 CFR 1910.212(a)(5) · Machine guarding |
Serious | $0 | $0 | Feb 28, 2018 | Final |
| Citation 1, item 3 29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements |
Serious | $0 | $0 | Feb 28, 2018 | Final |
| Citation 1, item 4 29 CFR 1910.303(f)(2) · Electrical equipment, general requirements |
Serious | $0 | $0 | Feb 28, 2018 | Final |
| Citation 1, item 5 29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods |
Serious | $0 | $0 | Feb 28, 2018 | Final |
| Citation 1, item 6 29 CFR 1910.305(e)(1) · Electrical wiring methods |
Serious | $0 | $0 | Feb 28, 2018 | Final |
| Citation 1, item 7 29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods |
Serious | $0 | $0 | Feb 28, 2018 | Final |
| Citation 2, item 1 29 CFR 12 NYCRR PART 801.30(A) |
Other-than-serious | $0 | $0 | Feb 28, 2018 | Final |
| Citation 2, item 2 29 CFR 1910.134(c)(2)(i) · Respiratory protection |
Other-than-serious | $0 | $0 | Feb 28, 2018 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.134(c)(2)(i)
(i) An employer may provide respirators at the request of employees or permit employees to use their own respirators, if the employer determines that such respirator use will not in itself create a hazard. If the employer determines that any voluntary respirator use is permissible, the employer shall provide the respirator users with the information contained in appendix D to this section (“Information for Employees Using Respirators When Not Required Under the Standard”); and
29 CFR 1910.151(c)
(c) Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use.
29 CFR 1910.212(a)(5)
(5) Exposure of blades. When the periphery of the blades of a fan is less than seven (7) feet above the floor or working level, the blades shall be guarded. The guard shall have openings no larger than one-half ( 1/2) inch.
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.