OSHA SearchOSHA records by employer

Ofs Fitel, LLC: OSHA inspections and violations

Carrollton, Georgia · Fiber Optic Cable Manufacturing · NAICS 335921

5inspections
3citation items
$9,179current penalties
Jun 22, 2021last inspection

OSHA has inspected Ofs Fitel, LLC 5 times in Georgia since 2016.

The latest one began on Jun 22, 2021 after a complaint, in Carrollton.

Those inspections ended with 3 citation items: 3 serious.

Penalties were first proposed at $15,299 and now stand at $9,179, 40% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Ofs Fitel, LLC averages $4,590 (2 cited inspections).

Ofs Fitel, LLC also files yearly injury logs with OSHA, summarized below.

It reported 4 severe injuries to OSHA since 2015.

Ofs Fitel, LLC: OSHA citation items per year, 2016 to 2021
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

148employers cited

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Ofs Fitel, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Company-wide record

OSHA records show Ofs Fitel, LLC at 3 sites in 2 states. Together they've had 6 inspections and $18,233 in current penalties.

We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.

Included with any plan: the site-by-site record for all 3 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.

See plans

Inspection history

Inspection 345377162 OPENED JUN 22, 2021Closed

Complaint · Partial · Safety · 513 employees at the site · Closed Oct 19, 2021

10 Brightwave Boulevard, Carrollton, GA 30117 · Fiber Optic Cable Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345120760 OPENED JAN 27, 2021Closed

Referral · Partial · Safety · 561 employees at the site · Closed Jun 22, 2021

10 Brightwave Blvd, Carrollton, GA 30117 · Fiber Optic Cable Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Jan 20, 2021: Employee suffers finger amputation by oscillator

At 3:35 p.m. on January 20, 2021, an employee, a 46-year-old stranding operator, was assessing a sudden stoppage of the oscillator machine, a machine that twists fiber optic cable buffer tubes around a central member to create a single cable. The tubes had become overtwisted, preventing the gears from turning. The employee touched the belt of a section of the machine to check its tension. The belt suddenly turned, pinching his finger against the machine. The employee was hospitalized to treat an amputation of the distal phalanx of the left middle finger.

No citations from this inspection.

Inspection 343197125 OPENED MAY 31, 2018Closed

Complaint · Partial · Health · 460 employees at the site · Closed Aug 8, 2018

2000 Northeastexpressway, Norcross, GA 30093 · Fiber Optic Cable Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(d)(1) · Walking-working surfaces
Serious$5,183$3,110Jul 12, 2018Final
Citation 1, item 2
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Serious$4,573$2,744Jul 12, 2018Final

Inspection 343004727 OPENED MAR 8, 2018Closed

Referral · Partial · Safety · 360 employees at the site · Closed Sep 14, 2018

10 Brightwave Blvd, Carrollton, GA 30117 · Fiber Optic Cable Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$5,543$3,326Aug 30, 2018Final

Inspection 341515179 OPENED JUN 1, 2016Closed

Referral · Partial · Safety · 410 employees at the site · Closed Jul 6, 2016

10 Brightwave Blvd, Carrollton, GA 30117 · Other Electronic Component Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2023, the Norcross site logged 2 recordable injuries or illnesses among about 445 workers: 0.5 per 100 full-time workers, against a median of 3.1 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
OFS Fitel, LLC
Norcross · 2023
445 200.53.1
OFS Fitel,LLC - OFC
Carrollton · 2023
5 000.00.6
OCS Division (Optical Connectivity Solutions)
Carrollton · 2020
111 000.00.5
Carrollton Cable
Carrollton · 2017
439 2155.21.5

Included with any plan: 2 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 4 reports on file.

Jan 20, 2021, Carrollton: Amputation · amputations · finger(s), fingernail(s), unspecified

An employee was standing near an oscillator unit while maintenance was being performed on it. The oscillator's belt made a forward motion and the employee's left hand was pinched between the belt and the belt wheel. The employee suffered a hand laceration and amputation of the left middle finger to the first knuckle.

Feb 28, 2018, Carrollton: Amputation · amputations · finger(s), fingernail(s), n.e.c.

An employee was loading a reel using take-up equipment when the equipment amputated the employee's right pinky finger. The equipment was not guarded at the time.

May 24, 2016, Carrollton: Hospitalization, amputation · amputations · finger(s), fingernail(s), n.e.c.

An employee was operating a fiber optic rewinder when his right index finger was caught and pulled by the machine. His finger was amputated above the knuckle.

Jul 5, 2015, Norcross: Amputation · amputations · finger(s), fingernail(s), n.e.c.

An employee's left finger was amputated while changing optical fiber spool for rewinding.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.133(a)(1)

(a) General requirements. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1910.22 · Walking-working surfaces

29 CFR 1910.22(d)(1)

(1) Walking-working surfaces are inspected, regularly and as necessary, and maintained in a safe condition;

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(g)(1)(iv)(a)

(A) As a substitute for the fixed wiring of a structure;

Other fiber optic cable manufacturing employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.