OSHA SearchOSHA records by employer

Ogden Brothers Construction Inc: OSHA inspections and violations

Naples, Florida · Masonry Contractors · NAICS 238140

5inspections
12citation items
$10,067current penalties
Aug 16, 2017last inspection

Since 2006, OSHA inspectors have visited Ogden Brothers Construction Inc in Florida 5 times.

The most recent inspection opened on Aug 16, 2017 as a planned inspection, in Naples.

In all, OSHA issued 12 citation items: 10 serious and 2 other-than-serious.

The proposed penalties came to $14,972; today they stand at $10,067, 33% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Ogden Brothers Construction Inc averages $1,738 across 1 cited inspection.

It reported 3 severe injuries to OSHA since 2015.

Ogden Brothers Construction Inc: OSHA citation items per year, 2006 to 2017
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

319employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Ogden Brothers Construction Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342560612 OPENED AUG 16, 2017Closed

Planned · Partial · Safety · 25 employees at the site · Closed Feb 8, 2018

1390 9th St N, Naples, FL 34101 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(13) · Ladders in construction
Serious$2,897$1,738Sep 21, 2017Final

Inspection 339627473 OPENED MAR 11, 2014Closed

Planned · Partial · Safety · 80 employees at the site · Closed Jun 4, 2014

4100 Tamiami Trail, Naples, FL 34103 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$3,500$2,100May 19, 2014Final

Inspection 313858540 OPENED SEP 15, 2009Closed

Planned · Partial · Safety · 5 employees at the site · Closed Oct 14, 2009

18700 Veterans Blvd, Port Charlotte, FL 33954 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,500$1,125Sep 17, 2009Closed
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,500$1,125Sep 17, 2009Closed
Citation 1, item 3
29 CFR 1926.451(f)(14) · Scaffolds, general requirements
Serious$1,500$1,125Sep 17, 2009Closed
Citation 1, item 4
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$1,500$1,125Sep 17, 2009Closed

Inspection 312735483 OPENED JAN 13, 2009Closed

Planned · Partial · Safety · 1 employee at the site · Closed Feb 24, 2009

444 Causeway Blvd., Belleair Beach, FL 33786 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$675$405Jan 26, 2009Closed
Citation 1, item 2
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$675$405Jan 26, 2009Closed
Citation 2, item 1
29 CFR 1926.1053(b)(16) · Ladders in construction
Other-than-serious$0$0Jan 26, 2009Closed

Inspection 309674000 OPENED JAN 6, 2006Closed

Unprogrammed related · Partial · Safety · 6 employees at the site · Closed Feb 10, 2006

15051 Punta Rassa Rd., Ft Myers, FL 33908 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$525$394Jan 17, 2006Closed
Citation 1, item 2
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$700$525Jan 17, 2006Closed
Citation 2, item 1
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Other-than-serious$0$0Jan 17, 2006Closed

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 3 reports on file.

Jun 26, 2025, Naples: Hospitalization · cuts, lacerations, punctures without injury to internal structures · multiple regions of the head

An employee was standing on temporary stair rails (wood) on the second floor of a building. The employee slipped and fell. To prevent himself from falling, he grabbed a freshly-installed concrete block, which then fell and struck the upper part of his face and head. The employee sustained lacerations to the face and skull.

Feb 17, 2022, Naples: Hospitalization · traumatic injuries and disorders, unspecified · nonclassifiable

An employee was cutting a piece of angle. The employee fell to the ground and was injured. The employee was hospitalized.

Aug 17, 2020, Naples: Hospitalization · cuts, lacerations · nonclassifiable

An employee was cutting a lintel with a chop saw. The saw kicked back and cut him.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(13)

(13) The top or top step of a stepladder shall not be used as a step.

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

Other masonry contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.