OSHA SearchOSHA records by employer

Old School Masonry, Inc.: OSHA inspections and violations

Conway, Arkansas · Masonry Contractors · NAICS 238140

1inspections
7citation items
$3,563current penalties
Aug 2, 2016last inspection

OSHA inspectors have visited Old School Masonry, Inc. in Arkansas one time.

It opened on Aug 2, 2016 as a planned inspection, in Conway.

In all, OSHA issued 7 citation items: 5 serious and 2 other-than-serious.

The proposed penalties came to $16,477; today they stand at $3,563, 78% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 6 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Old School Masonry, Inc. averages $3,563 across 1 cited inspection.

Old School Masonry, Inc.: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Arkansas · latest 90 days of OSHA records

17employers cited

Get notified the morning OSHA posts each new citation in Arkansas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Arkansas

Checking a subcontractor, a client or your own company? Watch Old School Masonry, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341665545 OPENED AUG 2, 2016Closed

Planned · Partial · Safety · 15 employees at the site · Closed Mar 14, 2018

3333 Dave Ward Dr, Conway, AR 72034 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(c)(1)(ii) · Scaffolds, general requirements
Serious$3,563$1,782Nov 23, 2016Final
Citation 1, item 1b
29 CFR 1926.451(e)(9)(iv) · Scaffolds, general requirements
Serious$3,563$0Nov 23, 2016Final
Citation 1, item 1c
29 CFR 1926.451(g)(1)(vi) · Scaffolds, general requirements
Serious$4,988$0Nov 23, 2016Final
Citation 1, item 2a
29 CFR 1926.451(h)(1) · Scaffolds, general requirements
Serious$3,563$1,782Nov 23, 2016Final
Citation 1, item 2b
29 CFR 1926.451(h)(2)(i) · Scaffolds, general requirements
Serious$0$0Nov 23, 2016Final
Citation 2, item 1
29 CFR 1926.451(b)(4) · Scaffolds, general requirements
Other-than-serious$400$0Nov 23, 2016Final
Citation 2, item 2
29 CFR 1926.452(c)(5)(iii) · Rules for each type of scaffold
Other-than-serious$400$0Nov 23, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(4)

(4) Each end of a platform, unless cleated or otherwise restrained by hooks or equivalent means, shall extend over the centerline of its support at least 6 inches (15 cm).

29 CFR 1926.451(c)(1)(ii)

(ii) Guys, ties, and braces shall be installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and be repeated vertically at locations of horizontal members every 20 feet (6.1 m) or less thereafter for scaffolds 3 feet (0.91 m) wide or less, and every 26 feet (7.9 m) or less thereafter for scaffolds greater than 3 feet (0.91 m) wide. The top guy, tie or brace of completed scaffolds shall be placed no further than the 4:1 height from the top. Such guys, ties and braces shall be installed at each end of the scaffold and at horizontal intervals not to exceed 30 feet (9.1 m) (measured from one end [not both] towards the other).

29 CFR 1926.451(e)(9)(iv)

(iv) Cross braces on tubular welded frame scaffolds shall not be used as a means of access or egress.

29 CFR 1926.452 · Rules for each type of scaffold

Other masonry contractors employers in Arkansas

Alert subscribers get notified of each newly cited employer in Arkansas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.