OSHA SearchOSHA records by employer

Oldcastle Precast, Inc. dba NC Products: OSHA inspections and violations

Raleigh, North Carolina · Concrete Pipe Manufacturing · NAICS 327332

6inspections
59citation items
$14,767current penalties
Sep 3, 2015last inspection

OSHA has inspected Oldcastle Precast, Inc. dba NC Products 6 times in North Carolina since 2000.

The latest one began on Sep 3, 2015 after a complaint, in Raleigh.

Those inspections ended with 59 citation items: 38 serious, 1 repeat and 20 other-than-serious.

Penalties were first proposed at $24,506 and now stand at $14,767, 40% lower after settlements or reviews.

Permit-required confined spaces comes up most often in these citations: 10 items under 1910.146.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Oldcastle Precast, Inc. dba NC Products averages $0 (1 cited inspection).

Oldcastle Precast, Inc. dba NC Products: OSHA citation items per year, 2000 to 2015
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

226employers cited

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Oldcastle Precast, Inc. dba NC Products and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340898840 OPENED SEP 3, 2015Closed

Complaint · Partial · Health · 29 employees at the site · Closed Dec 21, 2016

920 Withers Road, Raleigh, NC 27603 · Concrete Pipe Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.253(b)(2)(iv) · Gas welding and cutting
Other-than-serious$0$0Oct 30, 2015Final
Citation 1, item 1b
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Other-than-serious$0$0Oct 30, 2015Final

Inspection 340899152 OPENED SEP 3, 2015Closed

Complaint · Partial · Safety · 29 employees at the site · Closed Oct 20, 2015

920 Withers Road, Raleigh, NC 27601 · Concrete Pipe Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 310499827 OPENED NOV 6, 2006Closed

Complaint · Partial · Health · 41 employees at the site · Closed Dec 10, 2006

1431 Products Road, Fuquay Varina, NC 27526 · Other Concrete Product Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 309314417 OPENED SEP 28, 2005Closed

Referral · Partial · Health · 47 employees at the site · Closed Apr 3, 2006

920 Withers Road, Raleigh, NC 27603 · Concrete Pipe Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Repeat$6,300$4,410Oct 26, 2005Closed
Citation 1, item 2
29 CFR 1910.23(a)(5) · Guarding floor and wall openings and holes
Serious$2,275$0Oct 26, 2005Closed
Citation 2, item 1 Other-than-serious$0$0Oct 26, 2005Closed

Inspection 309314565 OPENED AUG 31, 2005Closed

Planned · Complete · Safety · 47 employees at the site · Closed Apr 12, 2006

920 Withers Road, Raleigh, NC 27603 · Concrete Pipe Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.146(d)(10) · Permit-required confined spaces
Serious$1,625$1,057Feb 3, 2006Closed
Citation 1, item 1b
29 CFR 1910.146(d)(14) · Permit-required confined spaces
Other-than-serious$0$0Feb 3, 2006Closed
Citation 1, item 1c
29 CFR 1910.146(g)(2)(i) · Permit-required confined spaces
Serious$0$0Feb 3, 2006Closed
Citation 1, item 1d
29 CFR 1910.146(g)(4) · Permit-required confined spaces
Serious$0$0Feb 3, 2006Closed
Citation 1, item 1e
29 CFR 1910.146(c)(7)(iii) · Permit-required confined spaces
Serious$0$0Feb 3, 2006Closed
Citation 1, item 1f
29 CFR 1910.147(c)(7)(iiia) · Lockout/tagout
Serious$0$0Feb 3, 2006Closed
Citation 1, item 2a
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Serious$1,625$1,057Feb 3, 2006Closed
Citation 1, item 2b
29 CFR 1910.335(b)(1) · Safeguards for personnel protection
Serious$0$0Feb 3, 2006Closed
Citation 1, item 2c
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Serious$0$0Feb 3, 2006Closed
Citation 2, item 1
29 CFR 1910.303(b)(1) · Electrical equipment, general requirements
Other-than-serious$0$0Feb 3, 2006Closed
Citation 2, item 3
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Feb 3, 2006Closed
Citation 2, item 4
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Other-than-serious$0$0Feb 3, 2006Closed

Inspection 303826515 OPENED AUG 21, 2000Closed

Planned · Complete · Health · 54 employees at the site · Closed Jan 23, 2001

920 Withers Road, Raleigh, NC 27603 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$813$528Nov 22, 2000Closed
Citation 1, item 2a
29 CFR 1910.23(a)(5) · Guarding floor and wall openings and holes
Serious$1,138$740Nov 22, 2000Closed
Citation 1, item 2b
29 CFR 1910.23(a)(7) · Guarding floor and wall openings and holes
Serious$0$0Nov 22, 2000Closed
Citation 1, item 2c
29 CFR 1910.23(a)(8)(i) · Guarding floor and wall openings and holes
Serious$0$0Nov 22, 2000Closed
Citation 1, item 2d
29 CFR 1910.23(c)(3) · Guarding floor and wall openings and holes
Serious$0$0Nov 22, 2000Closed
Citation 1, item 3
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$1,138$740Nov 22, 2000Closed
Citation 1, item 4a
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Serious$1,138$740Nov 22, 2000Closed
Citation 1, item 4b
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Serious$0$0Nov 22, 2000Closed
Citation 1, item 4c
29 CFR 1910.252(b)(2)(ia) · Welding fire safety
Serious$0$0Nov 22, 2000Closed
Citation 1, item 4d
29 CFR 1910.252(b)(3) · Welding fire safety
Serious$0$0Nov 22, 2000Closed
Citation 1, item 5a
29 CFR 1910.146(g)(2)(i) · Permit-required confined spaces
Serious$1,138$740Nov 22, 2000Closed
Citation 1, item 5b
29 CFR 1910.146(c)(2) · Permit-required confined spaces
Serious$0$0Nov 22, 2000Closed
Citation 1, item 5c
29 CFR 1910.146(d)(2) · Permit-required confined spaces
Serious$0$0Nov 22, 2000Closed
Citation 1, item 5d
29 CFR 1910.146(e)(1) · Permit-required confined spaces
Serious$0$0Nov 22, 2000Closed
Citation 1, item 5e
29 CFR 1910.146(d)(5)(i) · Permit-required confined spaces
Serious$0$0Nov 22, 2000Closed
Citation 1, item 6a
29 CFR 1910.147(f)(3)(i) · Lockout/tagout
Serious$1,138$740Nov 22, 2000Closed
Citation 1, item 6b
29 CFR 1910.147(c)(5)(i) · Lockout/tagout
Serious$0$0Nov 22, 2000Closed
Citation 1, item 6c
29 CFR 1910.147(c)(5)(ii) · Lockout/tagout
Serious$0$0Nov 22, 2000Closed
Citation 1, item 6d
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$0$0Nov 22, 2000Closed
Citation 1, item 6e
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$0$0Nov 22, 2000Closed
Citation 1, item 7a
29 CFR 1910.151(c) · First aid and eyewash
Serious$1,138$740Nov 22, 2000Closed
Citation 1, item 7b
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$0$0Nov 22, 2000Closed
Citation 1, item 8 Serious$813$528Nov 22, 2000Closed
Citation 1, item 9a
29 CFR 1910.212(a)(1) · Machine guarding
Serious$813$528Nov 22, 2000Closed
Citation 1, item 9b
29 CFR 1910.212(b) · Machine guarding
Serious$0$0Nov 22, 2000Closed
Citation 1, item 10
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$1,138$740Nov 22, 2000Closed
Citation 1, item 11
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$1,138$740Nov 22, 2000Closed
Citation 1, item 12a
29 CFR 1910.333(c)(2) · Working near live electrical parts
Serious$1,138$740Nov 22, 2000Closed
Citation 1, item 12b
29 CFR 1910.333(a)(2) · Working near live electrical parts
Serious$0$0Nov 22, 2000Closed
Citation 2, item 1 Other-than-serious$0$0Nov 22, 2000Closed
Citation 2, item 2
29 CFR 1910.133(a)(3) · Eye and face protection
Other-than-serious$0$0Nov 22, 2000Closed
Citation 2, item 3a
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$0$0Nov 22, 2000Closed
Citation 2, item 3b
29 CFR 1910.134(d)(1)(ii) · Respiratory protection
Other-than-serious$0$0Nov 22, 2000Closed
Citation 2, item 4
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Nov 22, 2000Closed
Citation 2, item 5
29 CFR 1910.242(a) · Hand and power tools
Other-than-serious$0$0Nov 22, 2000Closed
Citation 2, item 6
29 CFR 1910.252(a)(1)(i) · Welding fire safety
Other-than-serious$0$0Nov 22, 2000Closed
Citation 2, item 7
29 CFR 1910.303(g)(1)(i) · Electrical equipment, general requirements
Other-than-serious$0$0Nov 22, 2000Closed
Citation 2, item 8a
29 CFR 1910.305(g)(1)(i) · Electrical wiring methods
Other-than-serious$0$0Nov 22, 2000Closed
Citation 2, item 8b
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Other-than-serious$0$0Nov 22, 2000Closed
Citation 2, item 9
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Other-than-serious$0$0Nov 22, 2000Closed
Citation 2, item 10
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Nov 22, 2000Closed
Citation 2, item 11
29 CFR 1910.1200(g)(1) · Hazard communication
Other-than-serious$0$0Nov 22, 2000Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(g)(1)

(g) Safety data sheets. (1) Chemical manufacturers and importers shall obtain or develop a safety data sheet for each hazardous chemical they produce or import. Employers shall have a safety data sheet in the workplace for each hazardous chemical which they use.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.132(a)

(a) Application. Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, shall be provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact.

29 CFR 1910.132(d)(1)

(d) Hazard assessment and equipment selection. (1) The employer shall assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE). If such hazards are present, or likely to be present, the employer shall:

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.184 · Slings

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.333 · Working near live electrical parts

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.335 · Safeguards for personnel protection

29 CFR 1910.95 · Noise

29 CFR 9501.2901

Other concrete pipe manufacturing employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.