OSHA SearchOSHA records by employer

Olivo Masonry, Inc.: OSHA inspections and violations

Richardson, Texas · Masonry Contractors · NAICS 238140

5inspections
20citation items
$12,730current penalties
Jan 9, 2015last inspection

OSHA has inspected Olivo Masonry, Inc. 5 times in Texas since 2002.

The latest one began on Jan 9, 2015 as a planned inspection, in Dripping Springs.

Those inspections ended with 20 citation items: 13 serious, 6 repeat and 1 other-than-serious.

Penalties were first proposed at $24,250 and now stand at $12,730, 48% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 12 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Olivo Masonry, Inc. averages $4,000 (1 cited inspection).

Olivo Masonry, Inc.: OSHA citation items per year, 2002 to 2015
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

399employers cited

13 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Olivo Masonry, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340173038 OPENED JAN 9, 2015Closed

Planned · Complete · Safety · 10 employees at the site · Closed Apr 30, 2018

13518 Hwy 290 W., Dripping Springs, TX 78620 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$1,600$800Jan 15, 2015Final
Citation 2, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Repeat$3,200$1,600Jan 15, 2015Final
Citation 2, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Repeat$3,200$1,600Jan 15, 2015Final

Inspection 335172581 OPENED JUL 10, 2012Closed

Planned · Partial · Safety · 3 employees at the site · Closed Jun 9, 2014

4709 W. Parker Rd., Plano, TX 75093 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$1,600$600Jul 19, 2012Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,600$600Jul 19, 2012Final
Citation 1, item 3
29 CFR 1926.451(f)(15) · Scaffolds, general requirements
Serious$2,800$1,800Jul 19, 2012Final
Citation 1, item 4
29 CFR 1926.452(w)(2) · Rules for each type of scaffold
Serious$1,600$600Jul 19, 2012Final

Inspection 309541688 OPENED JAN 8, 2007Closed

Planned · Partial · Health · 6 employees at the site · Closed Mar 24, 2010

5834 Richmond Ave., Dallas, TX 75206 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.100(a) · Hard hats in construction
Repeat$1,600$960Mar 27, 2007Closed
Citation 1, item 1b
29 CFR 1926.451(h)(1) · Scaffolds, general requirements
Repeat$0$0Mar 27, 2007Closed
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Repeat$1,600$960Mar 27, 2007Closed
Citation 1, item 3
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Repeat$2,000$0Mar 27, 2007Closed

Inspection 309538304 OPENED MAY 22, 2006Closed

Planned · Partial · Safety · 11 employees at the site · Closed Aug 5, 2010

1650 Market Place Blvd., Irving, TX 75063 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.100(a) · Hard hats in construction
Serious$600$600Sep 8, 2006Closed
Citation 1, item 1b
29 CFR 1926.250(b)(5) · General requirements for storage
Serious$0$0Sep 8, 2006Closed
Citation 1, item 1c
29 CFR 1926.451(h)(1) · Scaffolds, general requirements
Serious$0$0Sep 8, 2006Closed
Citation 1, item 2a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$750$750Sep 8, 2006Closed
Citation 1, item 2b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Sep 8, 2006Closed
Citation 1, item 3
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$750$750Sep 8, 2006Closed
Citation 1, item 4
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$750$750Sep 8, 2006Closed
Citation 2, item 1
29 CFR 1926.416(e)(1) · Electrical safety in construction
Other-than-serious$0$0Sep 8, 2006Closed

Inspection 303915318 OPENED MAR 28, 2002Closed

Unprogrammed other · Partial · Safety · 9 employees at the site · Closed Jul 9, 2002

429 Belle Grove, Richardson, TX 75080 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$600$360Apr 12, 2002Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.250 · General requirements for storage

29 CFR 1926.250(b)(5)

(5) Materials shall not be stored on scaffolds or runways in excess of supplies needed for immediate operations.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

Other masonry contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.