OSHA SearchOSHA records by employer

Optima Reengineering & Project Management: OSHA inspections and violations

New Hartford, New York · Commercial and Institutional Building Construction · NAICS 236220

1inspections
4citation items
$4,200current penalties
Apr 28, 2016last inspection

OSHA inspectors have visited Optima Reengineering & Project Management in New York one time.

It opened on Apr 28, 2016 after a complaint, in New Hartford.

In all, OSHA issued 4 citation items: 4 serious.

The proposed penalties came to $6,000; today they stand at $4,200, 30% less.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Optima Reengineering & Project Management averages $4,200 across 1 cited inspection.

Optima Reengineering & Project Management: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

361employers cited

13 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Optima Reengineering & Project Management and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341445989 OPENED APR 28, 2016Closed

Complaint · Complete · Safety · 14 employees at the site · Closed Aug 4, 2016

1 Sangertown Square, Billy Beez, New Hartford, NY 13413 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$1,600$1,120May 18, 2016Final
Citation 1, item 1b
29 CFR 1926.405(a)(2)(ii)(i) · Job-site wiring
Serious$0$0May 18, 2016Final
Citation 1, item 2
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$2,000$1,400May 18, 2016Final
Citation 1, item 3
29 CFR 1926.602(c)(1)(ii) · Earthmovers and forklifts in construction
Serious$2,400$1,680May 18, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(a)(2)(ii)(i)

(iii) Guarding. For temporary wiring over 600 volts, nominal, fencing, barriers, or other effective means shall be provided to prevent access of other than authorized and qualified personnel.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(g)(1)(vii)

(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.

29 CFR 1926.602 · Earthmovers and forklifts in construction

Other commercial and institutional building construction employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.