OSHA SearchOSHA records by employer

Optimum Stucco Inc.: OSHA inspections and violations

Miami Beach, Florida · Masonry Contractors · NAICS 238140

2inspections
8citation items
$9,684current penalties
Jul 24, 2019last inspection

Since 2019, OSHA inspectors have visited Optimum Stucco Inc. in Florida 2 times.

The most recent inspection opened on Jul 24, 2019 as a planned inspection, in North Miami.

In all, OSHA issued 8 citation items: 8 serious.

The proposed penalties came to $19,323; today they stand at $9,684, 50% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 6 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Optimum Stucco Inc. averages $4,842 across 2 cited inspections.

Optimum Stucco Inc.: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

320employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Optimum Stucco Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344176904 OPENED JUL 24, 2019Closed

Planned · Partial · Safety · 4 employees at the site · Closed Sep 28, 2021

13890 Ne 3rd Crt. #418, North Miami, FL 33161 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$2,273$1,140Aug 16, 2019Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,273$1,140Aug 16, 2019Final
Citation 1, item 3
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$2,273$1,140Aug 16, 2019Final

Inspection 343988101 OPENED MAY 7, 2019Closed

Unprogrammed related · Partial · Safety · 8 employees at the site · Closed Sep 28, 2021

5288 Alton Rd., Miami Beach, FL 33140 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$2,842$1,421Nov 6, 2019Final
Citation 1, item 2a
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$2,842$1,421Nov 6, 2019Final
Citation 1, item 2b
29 CFR 1926.454(b) · Scaffold training
Serious$0$0Nov 6, 2019Final
Citation 1, item 3
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$2,842$1,421Nov 6, 2019Final
Citation 1, item 4
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,978$2,001Nov 6, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

Other masonry contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.