Orizon Aerostructures: OSHA inspections and violations
Grove, Oklahoma · Search, Detection, Navigation, Guidance, Aeronautical, and Nautical System and Instrument Manufacturing · NAICS 334511
1inspections
2citation items
$7,433current penalties
Jun 21, 2023last inspection
OSHA inspectors have visited Orizon Aerostructures in Oklahoma one time.
It opened on Jun 21, 2023 as a planned inspection, in Grove.
In all, OSHA issued 2 citation items: 2 serious.
The proposed penalties came to $12,388; today they stand at $7,433, 40% less.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Orizon Aerostructures averages $7,433 across 1 cited inspection.
Orizon Aerostructures also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Oklahoma · latest 90 days of OSHA records
58employers cited
Get notified the morning OSHA posts each new citation in Oklahoma: the employer, the site address, the rules broken and the penalty.
OSHA records show Orizon Aerostructures at 2 sites in 2 states. Together they've had 3 inspections and $12,256 in current penalties.
We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.
Included with any plan: the site-by-site record for all 2 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.
Planned · Complete · Safety · 500 employees at the site · Closed Oct 24, 2023
500 Industrial Rd A, Grove, OK 74344 · Search, Detection, Navigation, Guidance, Aeronautical, and Nautical System and Instrument Manufacturing · OSHA's record · Phone and website on Google Maps
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2016, the Grove site logged 6 recordable injuries or illnesses among about 144 workers: 4.1 per 100 full-time workers, against a median of 1.1 for its industry.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Orizon - Grove
Grove · 2016
144
6
0
4.1
1.1
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
(ii)(a) A safety guard shall cover the spindle end, nut and flange projections. The safety guard shall be mounted so as to maintain proper alignment with the wheel, and the strength of the fastenings shall exceed the strength of the guard.
(4) Oxygen storage. (i) Oxygen cylinders shall not be stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near any other substance likely to cause or accelerate fire; or in an acetylene generator compartment.
Other search, detection, navigation, guidance, aeronautical, and nautical system and instrument manufacturing employers in Oklahoma
Alert subscribers get notified of each newly cited employer in Oklahoma the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.