OSHA SearchOSHA records by employer

Orkin Pest Control: OSHA inspections and violations

Sioux City, Iowa · Exterminating and Pest Control Services · NAICS 561710

2inspections
4citation items
$13,000current penalties
Oct 12, 2020last inspection

OSHA has inspected Orkin Pest Control 2 times in Iowa since 1984.

The latest one began on Oct 12, 2020 on a referral, in Cedar Rapids.

Those inspections ended with 4 citation items: 4 other-than-serious.

Penalties were first proposed at $10,229 and still stand at $13,000.

Respiratory protection comes up most often in these citations: 2 items under 1910.134.

How that compares: the median penalty per cited inspection for staffing, cleaning and waste services employers since 2015 is $2,215, and Orkin Pest Control averages $13,000 (1 cited inspection).

Orkin Pest Control: OSHA citation items per year, 1984 to 2020
Citation items per year, by inspection date.

Iowa · latest 90 days of OSHA records

64employers cited

Get notified the morning OSHA posts each new citation in Iowa: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Iowa

Checking a subcontractor, a client or your own company? Watch Orkin Pest Control and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344969811 OPENED OCT 12, 2020Closed

Referral · Partial · Health · 21 employees at the site · Closed Feb 25, 2021

520 Limerock Dr. Sw, Cedar Rapids, IA 52405 · Exterminating and Pest Control Services · OSHA's record · Phone and website on Google Maps

Incident on Oct 2, 2020: Employee becomes ill from co exposure when using vacuum in a

At 1:30 p.m. on October 2, 2020, an employee working as a pest control operator for an extermination service was using a gasoline-powered fiber-moving vacuum to remove fiberglass insulation from an attic. The employee and Coworker #1 set up the vacuum inside the garage with the garage door open. The hatch used to access the attic was located in the garage. The employee was in the attic removing insulation with the vacuum and Coworker #1 was in the garage ensuring that the tubing did not clog. After completing the job, the employee left the attic and was acting abnormally. The Coworker #1 called Coworker #2 (manager) and dialed 911. An ambulance arrived and began treating the employee before transporting him to the hospital. The employee was hospitalized to treat carbon monoxide (CO) exposure.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.1000(a)(2) · Air contaminants
Other-than-serious$10,229$13,000Jan 28, 2021Final
Citation 1, item 1b
29 CFR 1910.1000(e) · Air contaminants
Other-than-serious$0$0Jan 28, 2021Final

Inspection 14766968 OPENED AUG 29, 1984Closed

Complaint · Partial · Health · 16 employees at the site · Closed Nov 7, 1984

611 11th Street, Sioux City, IA 51105 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(b)(10) · Respiratory protection
Other-than-serious$0$0Sep 11, 1984Closed
Citation 1, item 1b
29 CFR 1910.134(e)(5) · Respiratory protection
Other-than-serious$0$0Sep 11, 1984Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1000 · Air contaminants

29 CFR 1910.1000(a)(2)

(2) Other substances—8-hour Time Weighted Averages. An employee's exposure to any substance in Table Z-1, the exposure limit of which is not preceded by a “C”, shall not exceed the 8-hour Time Weighted Average given for that substance in any 8-hour work shift of a 40-hour work week.

29 CFR 1910.1000(e)

(e) To achieve compliance with paragraphs (a) through (d) of this section, administrative or engineering controls must first be determined and implemented whenever feasible. When such controls are not feasible to achieve full compliance, protective equipment or any other protective measures shall be used to keep the exposure of employees to air contaminants within the limits prescribed in this section. Any equipment and/or technical measures used for this purpose must be approved for each particular use by a competent industrial hygienist or other technically qualified person. Whenever respirators are used, their use shall comply with 1910.134.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(b)(10)

(10) Filters used for quantitative fit testing shall be replaced whenever increased breathing resistance is encountered, or when the test agent has altered the integrity of the filter media.

Other exterminating and pest control services employers in Iowa

Alert subscribers get notified of each newly cited employer in Iowa the morning it is posted. See the alert plans.