OSHA SearchOSHA records by employer

Orlando Mora: OSHA inspections and violations

Waldorf, Maryland · Framing Contractors · NAICS 238130

1inspections
5citation items
$874current penalties
Aug 10, 2021last inspection

OSHA inspectors have visited Orlando Mora in Maryland one time.

It opened on Aug 10, 2021 as a planned inspection, in Waldorf and is still open.

In all, OSHA issued 5 citation items: 2 serious and 3 other-than-serious.

The penalties, $874 in total, stand where OSHA first set them.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Orlando Mora averages $874 across 1 cited inspection.

Orlando Mora: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

Want to know if OSHA cites Orlando Mora again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 345468565 OPENED AUG 10, 2021Open

Planned · Complete · Safety · 4 employees at the site · Open

3510 Crain Hwy, Waldorf, MD 20603 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$437$437Sep 7, 2021Final
Citation 1, item 2
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$437$437Sep 7, 2021Final
Citation 2, item 1
29 CFR 1926.404(b)(1)(iii)(c) · Ground-fault protection on job sites
Other-than-serious$0$0Sep 7, 2021Final
Citation 2, item 2
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Other-than-serious$0$0Sep 7, 2021Final
Citation 2, item 3
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$0$0Sep 7, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(iii)(c)

(C) Each cord set, attachment cap, plug and receptacle of cord sets, and any equipment connected by cord and plug, except cord sets and receptacles which are fixed and not exposed to damage, shall be visually inspected before each day's use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage. Equipment found damaged or defective shall not be used until repaired.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(g)(2)(iv)

(iv) Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(g)(1)(vii)

(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other framing contractors employers in Maryland