OSHA SearchOSHA records by employer

Orr Construction Inc: OSHA inspections and violations

Guthrie, Oklahoma · Oil and Gas Pipeline and Related Structures Construction · NAICS 237120

5inspections
8citation items
$56,547current penalties
Feb 25, 2025last inspection

Since 2022, OSHA inspectors have visited Orr Construction Inc in Oklahoma 5 times.

The most recent inspection opened on Feb 25, 2025 as a planned inspection, in Ada.

In all, OSHA issued 8 citation items: 5 serious and 3 repeat.

The proposed penalties came to $113,184; today they stand at $56,547, 50% less.

The rule cited most here is 1926.651 (excavations), 5 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Orr Construction Inc averages $18,849 across 3 cited inspections.

Orr Construction Inc: OSHA citation items per year, 2022 to 2025
Citation items per year, by inspection date.

Want to know if OSHA cites Orr Construction Inc again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 348062621 OPENED FEB 25, 2025Closed

Planned · Partial · Safety · 60 employees at the site · Closed Mar 3, 2025

1230 N Mississippi Ave, Ada, OK 74820 · Oil and Gas Pipeline and Related Structures Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 347932485 OPENED DEC 12, 2024Closed

Planned · Partial · Safety · 60 employees at the site · Closed Jun 18, 2025

507 North First Street, Anadarko, OK 73005 · Oil and Gas Pipeline and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(k)(1) · Excavations
Serious$9,931$4,965Jun 6, 2025Final
Citation 2, item 1
29 CFR 1926.651(c)(2) · Excavations
Repeat$23,170$11,585Jun 6, 2025Final
Citation 2, item 2
29 CFR 1926.651(j)(2) · Excavations
Repeat$19,862$9,931Jun 6, 2025Final
Citation 2, item 3
29 CFR 1926.652(a)(1) · Trench protection
Repeat$23,170$11,585Jun 6, 2025Final

Inspection 346837230 OPENED JUL 17, 2023Closed

Follow-up · Partial · Safety · 45 employees at the site · Closed Jul 21, 2023

3855 S Harrah Rd, Harrah, OK 73045 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 346556897 OPENED MAR 7, 2023Closed

Follow-up · Partial · Safety · 46 employees at the site · Closed Sep 19, 2023

Broadway & Main St., Elk City, OK 73644 · Oil and Gas Pipeline and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.652(a)(1) · Trench protection
Serious$31,250$15,000May 17, 2023Final

Inspection 346020050 OPENED JUN 10, 2022Closed

Planned · Complete · Safety · 41 employees at the site · Closed Jun 1, 2023

35.87898 N, -97.40206 W Southwest Corner Of Blake St And Us-33, Guthrie, OK 73044 · Oil and Gas Pipeline and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.651(c)(2) · Excavations
Serious$5,801$3,481Nov 18, 2022Final
Citation 1, item 1b
29 CFR 1926.651(j)(2) · Excavations
Serious$0$0Nov 18, 2022Final
Citation 1, item 1c
29 CFR 1926.652(a)(1) · Trench protection
Serious$0$0Nov 18, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.651(j)(2)

(2) Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.

29 CFR 1926.651(k)(1)

(k) Inspections. (1) Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.

29 CFR 1926.652 · Trench protection

Other oil and gas pipeline and related structures construction employers in Oklahoma

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.