OSHA SearchOSHA records by employer

Ortiz Construction Inc.: OSHA inspections and violations

Brewer, Maine · Other Building Finishing Contractors · NAICS 238390

1inspections
6citation items
$8,702current penalties
Aug 24, 2022last inspection

OSHA inspectors have visited Ortiz Construction Inc. in Maine one time.

It opened on Aug 24, 2022 as a planned inspection, in Brewer.

In all, OSHA issued 6 citation items: 3 serious and 3 other-than-serious.

The penalties, $8,702 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Ortiz Construction Inc. averages $8,702 across 1 cited inspection.

Ortiz Construction Inc.: OSHA citation items per year, 2022 to 2022
Citation items per year, by inspection date.

Maine · latest 90 days of OSHA records

32employers cited

Get notified the morning OSHA posts each new citation in Maine: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maine

Checking a subcontractor, a client or your own company? Watch Ortiz Construction Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346171143 OPENED AUG 24, 2022Closed

Planned · Partial · Safety · 5 employees at the site · Closed Sep 30, 2026

554 South Main St., Brewer, ME 04412 · Other Building Finishing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$4,351$4,351Dec 12, 2022Final
Citation 1, item 2a
29 CFR 1926.502(d)(15) · Fall protection systems
Serious$4,351$4,351Dec 12, 2022Final
Citation 1, item 2b
29 CFR 1926.502(d)(21) · Fall protection systems
Serious$0$0Dec 12, 2022Final
Citation 2, item 1
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Other-than-serious$0$0Dec 12, 2022Final
Citation 2, item 2
29 CFR 1926.451(b)(3) · Scaffolds, general requirements
Other-than-serious$0$0Dec 12, 2022Final
Citation 2, item 3
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Other-than-serious$0$0Dec 12, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(b)(3)

(3) Except as provided in paragraphs (b)(3) (i) and (ii) of this section, the front edge of all platforms shall not be more than 14 inches (36 cm) from the face of the work, unless guardrail systems are erected along the front edge and/or personal fall arrest systems are used in accordance with paragraph (g) of this section to protect employees from falling.

29 CFR 1926.451(g)(1)

(g) Fall protection. (1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1) (i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.502 · Fall protection systems