Inspection 348824590 OPENED MAR 20, 2026Closed
19802 Moonflower Meadow St., Cypress, TX 77433 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
OSHA has inspected Oscar Quirino 2 times in Texas since 2025.
The latest one began on Mar 20, 2026 to follow up on an earlier case, in Cypress.
Those inspections ended with 3 citation items: 1 serious and 2 repeat.
Penalties were first proposed at $26,387 and still stand at $26,387.
Scaffolds, general requirements comes up most often in these citations: 3 items under 1926.451.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Oscar Quirino averages $26,387 (1 cited inspection).
Texas · latest 90 days of OSHA records
401employers cited
14 of them in the same industry
Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Texas
Checking a subcontractor, a client or your own company? Watch Oscar Quirino and get notified the morning OSHA posts a new citation for it.
Watch this company19802 Moonflower Meadow St., Cypress, TX 77433 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
19802 Moonflower Meadow St., Cypress, TX 77433 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(g)(1)(vi) · Scaffolds, general requirements |
Serious | $5,958 | $5,958 | Dec 9, 2025 | Final |
| Citation 2, item 1 29 CFR 1926.451(b)(1) · Scaffolds, general requirements |
Repeat | $11,916 | $11,916 | Dec 9, 2025 | Final |
| Citation 2, item 2 29 CFR 1926.451(e)(1) · Scaffolds, general requirements |
Repeat | $8,513 | $8,513 | Dec 9, 2025 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.451(b)(1)
(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:
29 CFR 1926.451(e)(1)
(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.
29 CFR 1926.451(g)(1)(vi)
(vi) Each employee performing overhand bricklaying operations from a supported scaffold shall be protected from falling from all open sides and ends of the scaffold (except at the side next to the wall being laid) by the use of a personal fall arrest system or guardrail system (with minimum 200 pound toprail capacity).
Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.