OSHA SearchOSHA records by employer

Oswego City DPW Traffic Shop: OSHA inspections and violations

Oswego, New York · Highway, Street, and Bridge Construction · NAICS 237310

4inspections
8citation items
$0current penalties
Sep 14, 2018last inspection

OSHA has inspected Oswego City DPW Traffic Shop 4 times in New York since 2018.

The latest one began on Sep 14, 2018 to follow up on an earlier case, in Oswego.

Those inspections ended with 8 citation items: 8 serious.

None of the citations carried a penalty.

Electrical wiring methods comes up most often in these citations: 3 items under 1910.305.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Oswego City DPW Traffic Shop averages $0 (1 cited inspection).

Oswego City DPW Traffic Shop: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

376employers cited

23 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Oswego City DPW Traffic Shop and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343481420 OPENED SEP 14, 2018Closed

Follow-up · Partial · Safety · Local government · 5 employees at the site · Closed Oct 18, 2018

80 East 9th St., Oswego, NY 13126 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343443628 OPENED SEP 4, 2018Closed

Monitoring · Partial · Safety · Local government · 34 employees at the site · Closed Sep 6, 2018

80 East 9th St., Oswego, NY 13126 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343213559 OPENED JUN 8, 2018Closed

Referral · Partial · Health · Local government · 90 employees at the site · Closed Jul 6, 2018

80 East 9th St., Oswego, NY 13126 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343190369 OPENED MAY 23, 2018Closed

Planned · Partial · Safety · Local government · 5 employees at the site · Closed Oct 18, 2018

Some St, Oswego, NY 13126 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Serious$0$0Aug 22, 2018Final
Citation 1, item 2
29 CFR 1910.106(d)(4)(iii) · Flammable liquids
Serious$0$0Aug 22, 2018Final
Citation 1, item 3
29 CFR 1910.106(d)(5)(i) · Flammable liquids
Serious$0$0Aug 22, 2018Final
Citation 1, item 4
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$0$0Aug 22, 2018Final
Citation 1, item 5
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Serious$0$0Aug 22, 2018Final
Citation 1, item 6
29 CFR 1910.305(b)(1)(i) · Electrical wiring methods
Serious$0$0Aug 22, 2018Final
Citation 1, item 7
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$0$0Aug 22, 2018Final
Citation 1, item 8
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Serious$0$0Aug 22, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.106(d)(4)(iii)

(iii) Wiring. Electrical wiring and equipment located in inside storage rooms used for Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be approved under subpart S of this part for Class I, Division 2 Hazardous Locations; for Category 3 flammable liquids with a flashpoint at or above 100 °F (37.8 °C) and Category 4 flammable liquids, shall be approved for general use.

29 CFR 1910.106(d)(5)(i)

(5) Storage inside building—(i) Egress. Flammable liquids, including stock for sale, shall not be stored so as to limit use of exits, stairways, or areas normally used for the safe egress of people.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

Other highway, street, and bridge construction employers in New York