OSHA SearchOSHA records by employer

Owl Creek Construction, LLC: OSHA inspections and violations

Myerstown, Pennsylvania · Roofing Contractors · NAICS 238160

1inspections
6citation items
$5,760current penalties
Mar 16, 2015last inspection

OSHA has inspected Owl Creek Construction, LLC once in Pennsylvania.

The inspection began on Mar 16, 2015 on a referral, in Myerstown.

That inspection ended with 6 citation items: 6 serious.

Penalties were first proposed at $9,600 and now stand at $5,760, 40% lower after settlements or reviews.

Ladders in construction comes up most often in these citations: 3 items under 1926.1053.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Owl Creek Construction, LLC averages $5,760 (1 cited inspection).

Owl Creek Construction, LLC: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

277employers cited

29 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Owl Creek Construction, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340465731 OPENED MAR 16, 2015Closed

Referral · Partial · Safety · 9 employees at the site · Closed May 2, 2016

2091 Camp Swatara Rd, Myerstown, PA 17067 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$1,600$960Apr 17, 2015Final
Citation 1, item 2
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$1,200$720Apr 17, 2015Final
Citation 1, item 3
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$2,000$1,200Apr 17, 2015Final
Citation 1, item 4
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,400$1,440Apr 17, 2015Final
Citation 1, item 5a
29 CFR 1926.1053(b)(6) · Ladders in construction
Serious$2,400$1,440Apr 17, 2015Final
Citation 1, item 5b
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$0$0Apr 17, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.1053(b)(6)

(6) Ladders shall be used only on stable and level surfaces unless secured to prevent accidental displacement.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.501 · Fall protection in construction

Other roofing contractors employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.