OSHA SearchOSHA records by employer

P-D Interiors, Inc.: OSHA inspections and violations

Charlottesville, Virginia · Drywall and Insulation Contractors · NAICS 238310

10inspections
11citation items
$4,864current penalties
Jul 17, 2024last inspection

Since 1995, OSHA inspectors have visited P-D Interiors, Inc. in Virginia 10 times.

The most recent inspection opened on Jul 17, 2024, in Charlottesville.

In all, OSHA issued 11 citation items: 11 serious.

The proposed penalties came to $8,890; today they stand at $4,864, 45% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 6 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. P-D Interiors, Inc. averages $1,343 across 1 cited inspection.

P-D Interiors, Inc.: OSHA citation items per year, 1995 to 2024
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

248employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch P-D Interiors, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347625493 OPENED JUL 17, 2024Closed

Unprogrammed other · Complete · Safety · 5 employees at the site · Closed Aug 15, 2024

345 250 Bypass, Charlottesville, VA 22901 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345824502 OPENED MAR 9, 2022Closed

Programmed other · Partial · Health · 24 employees at the site · Closed Jul 28, 2022

818 East Jefferson Street, Charlottesville, VA 22901 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1101(k)(9)(iii) · Asbestos in construction
Serious$2,685$1,343Apr 28, 2022Final

Inspection 344202346 OPENED JUN 28, 2019Closed

Unprogrammed other · Complete · Health · 6 employees at the site · Closed Jul 1, 2019

401 Alderman Rd., Charlottesville, VA 22903 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340049386 OPENED OCT 30, 2014Closed

Planned · Partial · Safety · 25 employees at the site · Closed Feb 12, 2015

100 Osage Lane Orbital Grill Restaurant, Waynesboro, VA 22980 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$315$220Dec 15, 2014Final
Citation 1, item 2a
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$420$294Dec 15, 2014Final
Citation 1, item 2b
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$0$0Dec 15, 2014Final
Citation 1, item 2c
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Dec 15, 2014Final
Citation 1, item 3
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$420$294Dec 15, 2014Final

Inspection 316471515 OPENED APR 17, 2012Closed

Planned · Complete · Safety · 65 employees at the site · Closed Apr 17, 2012

1215 Lee Street, Charlottesville, VA 22901 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 312307200 OPENED JUN 9, 2008Closed

Unprogrammed related · Partial · Safety · 2 employees at the site · Closed Jul 7, 2008

Thomas Jefferson Parkway, Public Safety Center, Palmyra, VA 22963 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 125445296 OPENED DEC 9, 1998Closed

Planned · Complete · Safety · 3 employees at the site · Closed Dec 18, 1998

200 Memorial Drive, Luray, VA 22835 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 126612084 OPENED MAR 26, 1998Closed

Referral · Complete · Safety · 5 employees at the site · Closed Jan 26, 1999

2596 Tinkling Springs, Stuarts Draft, VA 24477 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b) · Fall protection in construction
Serious$1,200$600Apr 8, 1998Closed
2 older inspections

Inspection 126612035 OPENED MAR 13, 1998Closed

Referral · Partial · Safety · 6 employees at the site · Closed Jan 26, 1999

2596 Tinkling Springs, Stuarts Draft, VA 24477 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,225$612Mar 23, 1998Closed

Inspection 126603745 OPENED JUN 26, 1995Closed

Planned · Partial · Safety · 2 employees at the site · Closed Sep 26, 1995

154 N. Main Street, Harrisonburg, VA 22801 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(a)(2) · Scaffolds, general requirements
Serious$875$500Jul 14, 1995Final
Citation 1, item 2
29 CFR 1926.451(a)(13) · Scaffolds, general requirements
Serious$875$500Jul 14, 1995Final
Citation 1, item 3
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Serious$875$500Jul 14, 1995Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1101 · Asbestos in construction

29 CFR 1926.1101(k)(9)(iii)

(iii) Training for Class I operations and for Class II operations that require the use of critical barriers (or equivalent isolation methods) and/or negative pressure enclosures under this section shall be the equivalent in curriculum, training method and length to the EPA Model Accreditation Plan (MAP) asbestos abatement workers training (40 CFR part 763, subpart E, appendix C).

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(13)

(a) Capacity. (1) Except as provided in paragraphs (a)(2), (a)(3), (a)(4), (a)(5) and (g) of this section, each scaffold and scaffold component shall be capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it.

29 CFR 1926.451(a)(2)

(2) Direct connections to roofs and floors, and counterweights used to balance adjustable suspension scaffolds, shall be capable of resisting at least 4 times the tipping moment imposed by the scaffold operating at the rated load of the hoist, or 1.5 (minimum) times the tipping moment imposed by the scaffold operating at the stall load of the hoist, whichever is greater.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

Other drywall and insulation contractors employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.