OSHA SearchOSHA records by employer

P Quality Stucco Inc.: OSHA inspections and violations

Kissimmee, Florida · Masonry Contractors · NAICS 238140

1inspections
4citation items
$5,543current penalties
May 17, 2018last inspection

OSHA inspectors have visited P Quality Stucco Inc. in Florida one time.

It opened on May 17, 2018, in Kissimmee.

In all, OSHA issued 4 citation items: 4 serious.

The penalties, $5,543 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. P Quality Stucco Inc. averages $5,543 across 1 cited inspection.

P Quality Stucco Inc.: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

321employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch P Quality Stucco Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343180881 OPENED MAY 17, 2018Closed

Unprogrammed other · Partial · Safety · 5 employees at the site · Closed Feb 20, 2019

2913 Fable St., Kissimmee, FL 34746 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$3,880$3,880Aug 8, 2018Final
Citation 1, item 1b
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Aug 8, 2018Final
Citation 1, item 1c
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Aug 8, 2018Final
Citation 1, item 2
29 CFR 1926.100(a) · Hard hats in construction
Serious$1,663$1,663Aug 8, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(g)(4)(i)

(i) Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.

29 CFR 1926.454 · Scaffold training

Other masonry contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.