Inspection 344735774 OPENED APR 28, 2020Closed
265 Penny Lane Ne, Rochester, MN 55906 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
OSHA has inspected Paces Lodging Corporation 4 times in Minnesota since 2017.
The latest one began on Apr 28, 2020 as a planned inspection, in Rochester.
Those inspections ended with 3 citation items: 2 serious and 1 repeat.
Penalties were first proposed at $10,350 and now stand at $9,495, 8% lower after settlements or reviews.
Stairways in construction comes up most often in these citations: 2 items under 1926.1052.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Paces Lodging Corporation averages $3,165 (3 cited inspections).
Want to know if OSHA cites Paces Lodging Corporation again? Add it to a watchlist and we will email you the morning the citation shows up.
Watch this company265 Penny Lane Ne, Rochester, MN 55906 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
100 Barnick Rd, Thief River Falls, MN 56701 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.405(b)(2) · Job-site wiring |
Serious | $1,650 | $1,155 | Jun 20, 2019 | Final |
415 Lake Shore Dr Ne, Bemidji, MN 56601 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.1052(c)(1) · Stairways in construction |
Repeat | $7,500 | $7,500 | Sep 19, 2017 | Final |
415 W Lake Shore Dr Ne, Bemidji, MN 56601 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.1052(c)(1) · Stairways in construction |
Serious | $1,200 | $840 | Jul 10, 2017 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.1052(c)(1)
(1) Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with:
29 CFR 1926.405(b)(2)
(2) Covers and canopies. All pull boxes, junction boxes, and fittings shall be provided with covers. If metal covers are used, they shall be grounded. In energized installations each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.