OSHA SearchOSHA records by employer

Pacific Coast Siding Inc: OSHA inspections and violations

Tigard, Oregon · Siding Contractors · NAICS 238170

15inspections
36citation items
$15,825current penalties
Nov 3, 2023last inspection

Since 1988, OSHA inspectors have visited Pacific Coast Siding Inc in Oregon 15 times.

The most recent inspection opened on Nov 3, 2023 as a planned inspection, in Forest Grove.

In all, OSHA issued 36 citation items: 28 serious, 1 repeat and 7 other-than-serious.

The penalties, $15,825 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 7 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Pacific Coast Siding Inc averages $935 across 3 cited inspections.

Pacific Coast Siding Inc: OSHA citation items per year, 1988 to 2023
Citation items per year, by inspection date.

Oregon · latest 90 days of OSHA records

396employers cited

Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oregon

Checking a subcontractor, a client or your own company? Watch Pacific Coast Siding Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347082729 OPENED NOV 3, 2023Closed

Planned · Partial · Safety · 1 employee at the site · Closed Apr 22, 2024

At Or Near 42761 Nw Dierickx Rd, Forest Grove, OR 97116 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR OAR 437-003-1501(1)
Serious$935$935Dec 11, 2023Final

Inspection 346459407 OPENED JAN 25, 2023Closed

Planned · Partial · Safety · 3 employees at the site · Closed Oct 10, 2023

9091 Sw Morrison St, Portland, OR 97225 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(6) · Ladders in construction
Serious$935$935Mar 30, 2023Final
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$935$935Mar 30, 2023Final

Inspection 341264414 OPENED FEB 18, 2016Closed

Planned · Complete · Safety · 3 employees at the site · Closed Jun 22, 2016

5025 N Amherst St, Portland, OR 97203 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(b)(1) · Electrical equipment on job sites
Other-than-serious$0$0Mar 23, 2016Final

Inspection 317696441 OPENED APR 9, 2014Closed

Planned · Partial · Safety · 3 employees at the site · Closed Aug 28, 2014

3733 N Baldwin St, Portland, OR 97217 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 7031501
Serious$840$840Jun 4, 2014Closed

Inspection 317066017 OPENED APR 17, 2013Closed

Planned · Partial · Safety · 8 employees at the site · Closed Oct 15, 2013

23890 Sw Robson Ter, Sherwood, OR 97140 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$840$840Jun 7, 2013Closed
Citation 1, item 2
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$840$840Jun 7, 2013Closed
Citation 1, item 3
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$840$840Jun 7, 2013Closed

Inspection 311706709 OPENED MAY 12, 2008Closed

Planned · Complete · Safety · 5 employees at the site · Closed Sep 12, 2008

41368 Gaffney Ln, Oregon City, OR 97045 · Siding Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 310686282 OPENED MAR 27, 2007Closed

Planned · Partial · Safety · 10 employees at the site · Closed Sep 6, 2007

901 Ne Addison St, Hillsboro, OR 97123 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 7031501
Serious$180$180May 15, 2007Closed
Citation 1, item 2
29 CFR 1926.1053(b)(10) · Ladders in construction
Serious$180$180May 15, 2007Closed
Citation 99, item 3 Other-than-serious$0$0May 15, 2007Closed

Inspection 309279784 OPENED NOV 28, 2005Closed

Accident · Partial · Safety · 3 employees at the site · Closed May 3, 2006

11710 Aerie Cresent Rd, Portland, OR 97266 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Incident on Nov 28, 2005: Employee is injured by falling scaffold

On November 28, 2005, Employee #1, a landscape worker, was struck by a vertical member of a pump jack scaffold assembly that fell over, while the scaffold was b eing disassembled. Employee #1 was hospitalized.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$500$500Jan 30, 2006Closed
Citation 1, item 1b
29 CFR 1926.21(b)(2) · Construction safety training
Serious$0$0Jan 30, 2006Closed
7 older inspections

Inspection 306464983 OPENED JUL 29, 2003Closed

Planned · Partial · Safety · 7 employees at the site · Closed Feb 13, 2004

Tukwila Dr Lot #74, Woodburn, OR 97071 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$375$375Aug 22, 2003Closed
Citation 1, item 2
29 CFR 1926.502(d)(15)(ii) · Fall protection systems
Serious$825$825Aug 22, 2003Closed
Citation 2, item 3
29 CFR 1926.451(g)(1)(i) · Scaffolds, general requirements
Repeat$3,000$3,000Aug 22, 2003Closed

Inspection 306630591 OPENED JUN 12, 2003Closed

Planned · Partial · Health · 3 employees at the site · Closed Jun 14, 2004

840 Nicole Ct, West Linn, OR 97068 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.59(e)(1) · Hazard communication
Other-than-serious$0$0Aug 19, 2003Closed
Citation 1, item 2
29 CFR 1926.103(d)(1)(iii) · Respiratory protection
Other-than-serious$0$0Aug 19, 2003Closed

Inspection 304106347 OPENED MAR 16, 2001Closed

Referral · Partial · Health · 6 employees at the site · Closed Apr 29, 2002

10600 Sw Kable St, Tigard, OR 97224 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.59(e)(1) · Hazard communication
Serious$165$165Aug 30, 2001Closed
Citation 1, item 1b
29 CFR 1926.59(h)(1) · Hazard communication
Serious$0$0Aug 30, 2001Closed
Citation 2, item 2
29 CFR 1926.103(e)(1) · Respiratory protection
Other-than-serious$0$0Aug 30, 2001Closed

Inspection 304106404 OPENED MAR 9, 2001Closed

Planned · Partial · Safety · 10 employees at the site · Closed Nov 21, 2001

10600 Sw Kable St, Tigard, OR 97224 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1)(i) · Scaffolds, general requirements
Serious$625$625Apr 25, 2001Closed
Citation 1, item 2 Serious$1,375$1,375Apr 25, 2001Closed
Citation 1, item 3
29 CFR 1926.452(k)(5) · Rules for each type of scaffold
Serious$375$375Apr 25, 2001Closed

Inspection 303601306 OPENED SEP 29, 2000Closed

Planned · Complete · Safety · 2 employees at the site · Closed Sep 25, 2002

10600 Sw Kable St, Tigard, OR 97224 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.50(d)(1) · Medical services and first aid
Serious$125$125Dec 28, 2000Final
Citation 1, item 1b
29 CFR 1926.50(e) · Medical services and first aid
Serious$0$0Dec 28, 2000Final
Citation 1, item 2a
29 CFR 1926.454(a) · Scaffold training
Serious$685$685Dec 28, 2000Final
Citation 1, item 2b
29 CFR 1926.454(b)(2) · Scaffold training
Serious$0$0Dec 28, 2000Final
Citation 1, item 2c
29 CFR 1926.1060(a)(1)(i) · Ladder and stairway training
Serious$0$0Dec 28, 2000Final
Citation 1, item 3a
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$1,250$1,250Dec 28, 2000Final
Citation 1, item 3b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Dec 28, 2000Final
Citation 1, item 3c
29 CFR 1926.452(k)(1) · Rules for each type of scaffold
Serious$0$0Dec 28, 2000Final
Citation 1, item 3d
29 CFR 1926.1053(b)(5)(i) · Ladders in construction
Serious$0$0Dec 28, 2000Final
Citation 1, item 3e
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$0$0Dec 28, 2000Final

Inspection 105252449 OPENED JAN 14, 1988Closed

Planned · Complete · Safety · 1 employee at the site · Closed Apr 1, 1988

901 Ne Addison St, Hillsboro, OR 97123 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 7831846
Other-than-serious$0$0Feb 23, 1988Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.103 · Respiratory protection

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(10)

(10) The top of a non-self-supporting ladder shall be placed with the two rails supported equally unless it is equipped with a single support attachment.

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.1060 · Ladder and stairway training

29 CFR 1926.21 · Construction safety training

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

29 CFR 1926.50 · Medical services and first aid

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.59 · Hazard communication

29 CFR 7010.7600

29 CFR 7010.7650

Other siding contractors employers in Oregon

Alert subscribers get notified of each newly cited employer in Oregon the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.