OSHA SearchOSHA records by employer

Package Design & Supply Co Inc: OSHA inspections and violations

Buffalo, New York · Corrugated and Solid Fiber Box Manufacturing · NAICS 322211

2inspections
5citation items
$9,000current penalties
Sep 17, 2024last inspection

Package Design & Supply Co Inc has 2 OSHA inspections on record in New York, the first in 2024.

OSHA's last visit started on Sep 17, 2024 to follow up on an earlier case, in Buffalo.

Across those inspections OSHA issued 5 citation items: 5 serious.

OSHA proposed $17,827 in penalties. After settlements and reviews the total is $9,000, down 50%.

Most often, OSHA cited 1910.147, lockout/tagout (3 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Package Design & Supply Co Inc averages $9,000 over 1 cited inspection in that time.

Package Design & Supply Co Inc also files yearly injury logs with OSHA, summarized below.

Package Design & Supply Co Inc: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

360employers cited

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Package Design & Supply Co Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347758799 OPENED SEP 17, 2024Closed

Follow-up · Partial · Safety · 29 employees at the site · Closed Sep 18, 2024

1014 Northampton Street, Buffalo, NY 14211 · Corrugated and Solid Fiber Box Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 347207110 OPENED JAN 10, 2024Closed

Planned · Partial · Safety · 29 employees at the site · Closed Mar 19, 2024

1014 Northampton Street, Buffalo, NY 14211 · Corrugated and Solid Fiber Box Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.28(b)(3)(iv) · Fall protection in general industry
Serious$5,485$2,500Feb 9, 2024Final
Citation 1, item 2
29 CFR 1910.29(b)(1) · Fall protection systems in general industry
Serious$5,485$2,500Feb 9, 2024Final
Citation 1, item 3a
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$6,857$4,000Feb 9, 2024Final
Citation 1, item 3b
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$0$0Feb 9, 2024Final
Citation 1, item 3c
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$0$0Feb 9, 2024Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Buffalo site logged 0 recordable injuries or illnesses among about 31 workers: 0.0 per 100 full-time workers, against a median of 2.1 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Package Design & Supply - Buffalo
Buffalo · 2025
31 000.02.1
Package Design & Supply
Buffalo · 2023
28 000.02.1
Package Design & Supply Co.-Main Facility
Buffalo · 2021
34 113.42.1

Included with any plan: 7 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.147(c)(7)(i)

(7) Training and communication. (i) The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following:

29 CFR 1910.28 · Fall protection in general industry

29 CFR 1910.29 · Fall protection systems in general industry

Other corrugated and solid fiber box manufacturing employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.