Inspection 348963000 OPENED MAY 28, 2026Open
21105 Se Archer Dr, Bend, OR 97702 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
Since 2021, OSHA inspectors have visited Pahlisch Commercial Inc in Oregon 4 times.
The most recent inspection opened on May 28, 2026 as a planned inspection, in Bend and is still open.
In all, OSHA issued 10 citation items: 8 serious and 2 other-than-serious.
The penalties, $4,375 in total, stand where OSHA first set them.
The rule cited most here is 1926.502 (fall protection systems), 5 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Pahlisch Commercial Inc averages $4,375 across 1 cited inspection.
Pahlisch Commercial Inc also files yearly injury logs with OSHA, summarized below.
Oregon · latest 90 days of OSHA records
397employers cited
8 of them in the same industry
Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Oregon
Checking a subcontractor, a client or your own company? Watch Pahlisch Commercial Inc and get notified the morning OSHA posts a new citation for it.
Watch this company21105 Se Archer Dr, Bend, OR 97702 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
63190 Deschutes Market Rd, Bend, OR 97701 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.502(b)(6) · Fall protection systems |
Serious | $1,290 | $1,290 | Nov 3, 2022 | Final |
| Citation 1, item 2a 29 CFR 1926.502(b)(2) · Fall protection systems |
Serious | $1,075 | $1,075 | Nov 3, 2022 | Final |
| Citation 1, item 2b 29 CFR 1926.502(b)(1) · Fall protection systems |
Serious | $0 | $0 | Nov 3, 2022 | Final |
| Citation 1, item 3a 29 CFR 1926.502(b)(5) · Fall protection systems |
Serious | $375 | $375 | Nov 3, 2022 | Final |
| Citation 1, item 3b 29 CFR 1926.502(b)(4) · Fall protection systems |
Serious | $0 | $0 | Nov 3, 2022 | Final |
| Citation 1, item 4 29 CFR OAR 437-003-2501(1)(C)-4 |
Serious | $180 | $180 | Nov 3, 2022 | Final |
| Citation 1, item 5 29 CFR 1926.403(b)(1) · Electrical equipment on job sites |
Serious | $180 | $180 | Nov 3, 2022 | Final |
| Citation 1, item 6 29 CFR OAR 437-001-0760(7)(A)-2 |
Serious | $1,075 | $1,075 | Nov 3, 2022 | Final |
| Citation 2, item 7 29 CFR OAR 437-003-0020(1) |
Other-than-serious | $200 | $200 | Nov 3, 2022 | Final |
| Citation 2, item 8 29 CFR 1926.150(c)(1)(viii) · Fire protection |
Other-than-serious | $0 | $0 | Nov 3, 2022 | Final |
63190 Deschutes Market Rd, Bend, OR 97702 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2353 Ne Holliday Ave, Bend, OR 97701 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2024, the Bend site logged 2 recordable injuries or illnesses among about 50 workers: 5.0 per 100 full-time workers, against a median of 1.8 for its industry. Those cases cost 11 days away from work.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Pahlisch Commercial Inc Bend · 2024 | 50 | 2 | 1 | 5.0 | 1.8 |
| Pahlisch Commercial Bend · 2023 | 55 | 1 | 1 | 1.4 | 1.8 |
Included with any plan: 2 more yearly logs from these sites, back to 2021, with each site's average rate over its latest three years. Already a subscriber? Sign in.
See plansCurrent text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.150(c)(1)(viii)
(viii) Portable fire extinguishers shall be inspected periodically and maintained in accordance with Maintenance and Use of Portable Fire Extinguishers, NFPA No. 10A-1970.
29 CFR 1926.403(b)(1)
(b) Examination, installation, and use of equipment—(1) Examination. The employer shall ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety of equipment shall be determined on the basis of the following considerations:
29 CFR 1926.502(b)(1)
(1) Top edge height of top rails, or equivalent guardrail system members, shall be 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level. When conditions warrant, the height of the top edge may exceed the 45-inch height, provided the guardrail system meets all other criteria of this paragraph.
Alert subscribers get notified of each newly cited employer in Oregon the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.