OSHA SearchOSHA records by employer

Painttech Inc.: OSHA inspections and violations

Depew, New York · Painting and Wall Covering Contractors · NAICS 238320

3inspections
5citation items
$4,226current penalties
Nov 10, 2021last inspection

Painttech Inc. has 3 OSHA inspections on record in New York, the first in 2004.

OSHA's last visit started on Nov 10, 2021 as a planned inspection, in Williamsville.

Across those inspections OSHA issued 5 citation items: 4 serious and 1 other-than-serious.

OSHA proposed $6,647 in penalties. After settlements and reviews the total is $4,226, down 36%.

Most often, OSHA cited 1926.453, aerial lifts (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,079. Painttech Inc. averages $1,922 over 2 cited inspections in that time.

Painttech Inc.: OSHA citation items per year, 2004 to 2021
Citation items per year, by inspection date.

Want to know if OSHA cites Painttech Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 345634745 OPENED NOV 10, 2021Closed

Planned · Partial · Safety · 7 employees at the site · Closed May 24, 2022

13 Hopkins Drive, Williamsville, NY 14221 · Painting and Wall Covering Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$1,989$1,492Jan 14, 2022Final

Inspection 341694487 OPENED AUG 9, 2016Closed

Planned · Complete · Safety · 2 employees at the site · Closed Oct 20, 2016

2429 Military Road, Niagara Falls, NY 14304 · Painting and Wall Covering Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$2,138$1,176Sep 19, 2016Final
Citation 1, item 2
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$2,138$1,176Sep 19, 2016Final

Inspection 308141043 OPENED OCT 27, 2004Closed

Planned · Complete · Safety · 2 employees at the site · Closed Nov 18, 2004

George Urban Blvd. & Dick Road, Depew, NY 14225 · Painting and Wall Covering Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$382$382Oct 29, 2004Closed
Citation 2, item 1
29 CFR 1926.152(a)(1) · Flammable liquids
Other-than-serious$0$0Oct 29, 2004Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.152 · Flammable liquids

29 CFR 1926.152(a)(1)

(a) General requirements. (1) Only approved containers and portable tanks shall be used for storage and handling of flammable liquids. Approved safety cans or Department of Transportation approved containers shall be used for the handling and use of flammable liquids in quantities of 5 gallons or less, except that this shall not apply to those flammable liquid materials which are highly viscid (extremely hard to pour), which may be used and handled in original shipping containers. For quantities of one gallon or less, the original container may be used, for storage, use and handling of flammable liquids.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.404(f)(6)

(6) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.

29 CFR 1926.453 · Aerial lifts

Other painting and wall covering contractors employers in New York

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.