OSHA SearchOSHA records by employer

Paiz Stucco Inc: OSHA inspections and violations

Westbury, New York · Masonry Contractors · NAICS 238140

1inspections
5citation items
$11,039current penalties
Oct 17, 2024last inspection

OSHA has inspected Paiz Stucco Inc once in New York.

The inspection began on Oct 17, 2024, in Westbury; the case is still open.

That inspection ended with 5 citation items: 4 serious and 1 other-than-serious.

Penalties were first proposed at $11,039 and still stand at $11,039.

Scaffolds, general requirements comes up most often in these citations: 2 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Paiz Stucco Inc averages $11,039 (1 cited inspection).

Paiz Stucco Inc: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

360employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Paiz Stucco Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347823338 OPENED OCT 17, 2024Open

Unprogrammed other · Partial · Safety · 1 employee at the site · Open

2 Hardy Lane, Westbury, NY 11590 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1)(v) · Scaffolds, general requirements
Serious$3,547$3,547Apr 3, 2025Final
Citation 1, item 2a
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$3,547$3,547Apr 3, 2025Final
Citation 1, item 2b
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Apr 3, 2025Final
Citation 1, item 3
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$3,547$3,547Apr 3, 2025Final
Citation 2, item 1
29 CFR 1903.19(c)(1) · Proving cited hazards were fixed
Other-than-serious$398$398Sep 18, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.19 · Proving cited hazards were fixed

29 CFR 1903.19(c)(1)

(c) Abatement certification. (1) Within 10 calendar days after the abatement date, the employer must certify to OSHA (the Agency) that each cited violation has been abated, except as provided in paragraph (c)(2) of this section.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(4)

(4) Ladders shall be used only for the purpose for which they were designed.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(g)(1)(v)

(v) Each employee on a walkway located within a scaffold shall be protected by a guardrail system (with minimum 200 pound toprail capacity) installed within 9 1/2 inches (24.1 cm) of and along at least one side of the walkway.

29 CFR 1926.454 · Scaffold training

Other masonry contractors employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.