Inspection 341436194 OPENED APR 27, 2016Closed
1572 Cr 45, Fulton, NY 13069 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
OSHA has inspected Palermo TN Highway Dept 19 times in New York since 1990.
The latest one began on Apr 27, 2016 to follow up on an earlier case, in Fulton.
Those inspections ended with 61 citation items: 35 serious and 26 other-than-serious.
None of the citations carried a penalty.
Electrical equipment, general requirements comes up most often in these citations: 7 items under 1910.303.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Palermo TN Highway Dept averages $0 (1 cited inspection).
New York · latest 90 days of OSHA records
360employers cited
21 of them in the same industry
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch Palermo TN Highway Dept and get notified the morning OSHA posts a new citation for it.
Watch this company1572 Cr 45, Fulton, NY 13069 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1572 Cr 45, Fulton, NY 13069 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements |
Serious | $0 | $0 | Apr 13, 2016 | Final |
| Citation 1, item 2 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Serious | $0 | $0 | Apr 13, 2016 | Final |
| Citation 1, item 3 29 CFR 1910.151(c) · First aid and eyewash |
Serious | $0 | $0 | Apr 13, 2016 | Final |
| Citation 1, item 4 29 CFR 1910.1200(f)(5)(i) · Hazard communication |
Serious | $0 | $0 | Apr 13, 2016 | Final |
| Citation 2, item 1 29 CFR 1910.37(b)(6) · Exit routes |
Other-than-serious | $0 | $0 | Apr 13, 2016 | Final |
1572 Cr 45, Fulton, NY 13069 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1572 Cr 45, Fulton, NY 13069 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.303(b)(1) · Electrical equipment, general requirements |
Serious | $0 | $0 | Apr 25, 2012 | Closed |
| Citation 1, item 2 29 CFR 1910.303(b)(8)(i) · Electrical equipment, general requirements |
Serious | $0 | $0 | Apr 25, 2012 | Closed |
| Citation 1, item 3 29 CFR 1910.334(a)(2)(ii) · Using electrical equipment |
Serious | $0 | $0 | Apr 25, 2012 | Closed |
| Citation 2, item 1 29 CFR 1910.244(a)(1)(ii) · Other portable tools and equipment |
Other-than-serious | $0 | $0 | Apr 25, 2012 | Closed |
1572 Cr 45, Fulton, NY 13069 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1572 Cr 45, Fulton, NY 13069 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.147(c)(1) · Lockout/tagout |
Serious | $0 | $0 | Jan 6, 2009 | Closed |
| Citation 1, item 2 29 CFR 1910.151(c) · First aid and eyewash |
Serious | $0 | $0 | Jan 6, 2009 | Closed |
| Citation 1, item 3 29 CFR 1910.305(e)(1) · Electrical wiring methods |
Serious | $0 | $0 | Jan 6, 2009 | Closed |
| Citation 1, item 4 29 CFR 1910.1200(h) · Hazard communication |
Serious | $0 | $0 | Jan 6, 2009 | Closed |
| Citation 2, item 1 29 CFR 1910.120(b)(1)(i) · Hazardous waste operations and emergency response |
Other-than-serious | $0 | $0 | Jan 6, 2009 | Closed |
| Citation 2, item 2 29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements |
Other-than-serious | $0 | $0 | Jan 6, 2009 | Closed |
| Citation 2, item 3 29 CFR 1910.132(f)(4) · Personal protective equipment, general requirements |
Other-than-serious | $0 | $0 | Jan 6, 2009 | Closed |
| Citation 2, item 4 29 CFR 1910.157(e)(3) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Jan 6, 2009 | Closed |
| Citation 2, item 5 29 CFR 1910.244(a)(1)(ii) · Other portable tools and equipment |
Other-than-serious | $0 | $0 | Jan 6, 2009 | Closed |
| Citation 2, item 6 29 CFR 1910.1200(f)(5)(i) · Hazard communication |
Other-than-serious | $0 | $0 | Jan 6, 2009 | Closed |
1572 Cr 45, Fulton, NY 13069 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1572 Cr 45, Fulton, NY 13069 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.141(b)(2)(i) · Sanitation |
Serious | $0 | $0 | Sep 15, 2003 | Closed |
| Citation 1, item 2 29 CFR 1910.141(b)(2)(iii) · Sanitation |
Serious | $0 | $0 | Sep 15, 2003 | Closed |
1572 Cr 45, Fulton, NY 13069 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1572 Cr 45, Fulton, NY 13069 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1572 Cr 45, Fulton, NY 13069 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.106(g)(3)(iii) · Flammable liquids |
Serious | $0 | $0 | Mar 28, 2003 | Closed |
| Citation 1, item 2 29 CFR 1910.106(g)(8) · Flammable liquids |
Serious | $0 | $0 | Mar 28, 2003 | Closed |
| Citation 1, item 3 29 CFR 1910.132(a) · Personal protective equipment, general requirements |
Serious | $0 | $0 | Mar 28, 2003 | Closed |
| Citation 1, item 4 29 CFR 1910.135 · Head protection |
Serious | $0 | $0 | Mar 28, 2003 | Closed |
| Citation 1, item 5 29 CFR 1910.147(c)(1) · Lockout/tagout |
Serious | $0 | $0 | Mar 28, 2003 | Closed |
| Citation 1, item 6 29 CFR 1910.252(b)(2)(iii) · Welding fire safety |
Serious | $0 | $0 | Mar 28, 2003 | Closed |
| Citation 1, item 7 29 CFR 1910.252(b)(3) · Welding fire safety |
Serious | $0 | $0 | Mar 28, 2003 | Closed |
| Citation 1, item 8 29 CFR 1910.334(a)(2)(i) · Using electrical equipment |
Serious | $0 | $0 | Mar 28, 2003 | Closed |
| Citation 2, item 1 29 CFR 8010007 |
Other-than-serious | $0 | $0 | Mar 28, 2003 | Closed |
| Citation 2, item 2 29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements |
Other-than-serious | $0 | $0 | Mar 28, 2003 | Closed |
| Citation 2, item 3 29 CFR 1910.151(c) · First aid and eyewash |
Other-than-serious | $0 | $0 | Mar 28, 2003 | Closed |
| Citation 2, item 4 29 CFR 1910.1200(h) · Hazard communication |
Other-than-serious | $0 | $0 | Mar 28, 2003 | Closed |
1572 Cr 45, Fulton, NY 13069 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1572 Cr 45, Fulton, NY 13069 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements |
Serious | $0 | $0 | Dec 1, 1992 | Closed |
| Citation 1, item 2 29 CFR 1910.305(b)(2) · Electrical wiring methods |
Serious | $0 | $0 | Dec 1, 1992 | Closed |
| Citation 1, item 3 29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods |
Serious | $0 | $0 | Dec 1, 1992 | Closed |
1572 Cr 45, Fulton, NY 13069 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1572 Cr 45, Fulton, NY 13069 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Serious | $0 | $0 | Mar 4, 1992 | Closed |
| Citation 2, item 1 29 CFR 1910.134(b)(4) · Respiratory protection |
Other-than-serious | $0 | $0 | Mar 4, 1992 | Closed |
| Citation 2, item 2 29 CFR 1910.134(b)(10) · Respiratory protection |
Other-than-serious | $0 | $0 | Mar 4, 1992 | Closed |
| Citation 2, item 3 29 CFR 1910.134(b)(6) · Respiratory protection |
Other-than-serious | $0 | $0 | Mar 4, 1992 | Closed |
| Citation 2, item 4 29 CFR 1910.134(f)(2)(iii) · Respiratory protection |
Other-than-serious | $0 | $0 | Mar 4, 1992 | Closed |
| Citation 2, item 5 29 CFR 1910.134(f)(4) · Respiratory protection |
Other-than-serious | $0 | $0 | Mar 4, 1992 | Closed |
1572 Cr 45, Fulton, NY 13069 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1572 Cr 45, Fulton, NY 13069 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.252(b)(4)(ix) · Welding fire safety |
Serious | $0 | $0 | Mar 14, 1991 | Closed |
| Citation 1, item 2 29 CFR 1910.303(b)(1) · Electrical equipment, general requirements |
Serious | $0 | $0 | Mar 14, 1991 | Closed |
| Citation 1, item 3 29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods |
Serious | $0 | $0 | Mar 14, 1991 | Closed |
1572 Cr 45, Fulton, NY 13069 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1572 Cr 45, Fulton, NY 13069 · General Automotive Repair · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.23(e)(1) · Guarding floor and wall openings and holes |
Serious | $0 | $0 | Mar 22, 1990 | Closed |
| Citation 1, item 2 29 CFR 1910.23(e)(2) · Guarding floor and wall openings and holes |
Serious | $0 | $0 | Mar 22, 1990 | Closed |
| Citation 1, item 3 29 CFR 1910.24(e) · Fixed industrial stairs |
Serious | $0 | $0 | Mar 22, 1990 | Closed |
| Citation 1, item 4 29 CFR 1910.108(g)(6)(iv) · [Reserved] |
Serious | $0 | $0 | Mar 22, 1990 | Closed |
| Citation 1, item 5 29 CFR 1910.177(d)(4) · Servicing multi-piece and single piece rim wheels |
Serious | $0 | $0 | Mar 22, 1990 | Closed |
| Citation 1, item 6 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Serious | $0 | $0 | Mar 22, 1990 | Closed |
| Citation 1, item 7 29 CFR 1926.251(c)(5) · Rigging equipment for material handling |
Serious | $0 | $0 | Mar 22, 1990 | Closed |
| Citation 2, item 1 | Other-than-serious | $0 | $0 | Mar 22, 1990 | Closed |
| Citation 2, item 2 29 CFR 1910.22(d)(1) · General requirements |
Other-than-serious | $0 | $0 | Mar 22, 1990 | Closed |
| Citation 2, item 3 29 CFR 1910.106(b)(3)(iv) · Flammable liquids |
Other-than-serious | $0 | $0 | Mar 22, 1990 | Closed |
| Citation 2, item 4 29 CFR 1910.144(a)(3) · Safety color code for marking physical hazards |
Other-than-serious | $0 | $0 | Mar 22, 1990 | Closed |
| Citation 2, item 5 29 CFR 1910.157(e)(4) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Mar 22, 1990 | Closed |
| Citation 2, item 6 29 CFR 1910.157(f)(16) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Mar 22, 1990 | Closed |
| Citation 2, item 7 29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Mar 22, 1990 | Closed |
| Citation 2, item 8 29 CFR 1910.1200(e)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Mar 22, 1990 | Closed |
| Citation 2, item 9 29 CFR 8010003 A01 |
Other-than-serious | $0 | $0 | Mar 22, 1990 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.106(g)(3)(iii)
(iii) Emergency power cutoff. A clearly identified and easily accessible switch(es) or a circuit breaker(s) shall be provided at a location remote from dispensing devices, including remote pumping systems, to shut off the power to all dispensing devices in the event of an emergency.
29 CFR 1910.106(g)(8)
(8) Sources of ignition. In addition to the previous restrictions of this paragraph, the following shall apply: There shall be no smoking or open flames in the areas used for fueling, servicing fuel systems for internal combustion engines, receiving or dispensing of flammable liquids. Conspicuous and legible signs prohibiting smoking shall be posted within sight of the customer being served. The motors of all equipment being fueled shall be shut off during the fueling operation.
29 CFR 1910.120(b)(1)(i)
(1) General. (i) Employers shall develop and implement a written safety and health program for their employees involved in hazardous waste operations. The program shall be designed to identify, evaluate, and control safety and health hazards, and provide for emergency response for hazardous waste operations.
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.