OSHA SearchOSHA records by employer

Palito Masonry, Inc: OSHA inspections and violations

Knoxville, Tennessee · Masonry Contractors · NAICS 238140

1inspections
2citation items
$1,500current penalties
Jun 9, 2015last inspection

OSHA has inspected Palito Masonry, Inc once in Tennessee.

The inspection began on Jun 9, 2015 as a planned inspection, in Knoxville.

That inspection ended with 2 citation items: 2 serious.

Penalties were first proposed at $1,500 and still stand at $1,500.

Scaffolds, general requirements comes up most often in these citations: 2 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Palito Masonry, Inc averages $1,500 (1 cited inspection).

Palito Masonry, Inc: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

342employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch Palito Masonry, Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340701127 OPENED JUN 9, 2015Closed

Planned · Complete · Safety · 9 employees at the site · Closed Aug 5, 2015

850 East Hill Avenue, Knoxville, TN 37915 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(a)(1) · Scaffolds, general requirements
Serious$750$750Jul 3, 2015Final
Citation 1, item 2
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$750$750Jul 3, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(1)

(a) Capacity. (1) Except as provided in paragraphs (a)(2), (a)(3), (a)(4), (a)(5) and (g) of this section, each scaffold and scaffold component shall be capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it.

29 CFR 1926.451(f)(7)

(7) Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person.

Other masonry contractors employers in Tennessee

Alert subscribers get notified of each newly cited employer in Tennessee the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.