Inspection 341981231 OPENED DEC 7, 2016Closed
93 Firth Lane, Palmyra, NJ 08065 · Facilities Support Services · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Palmyra, New Jersey · Facilities Support Services · NAICS 561210
Palmyra Borough DPW has 2 OSHA inspections on record in New Jersey, the first in 2016.
OSHA's last visit started on Dec 7, 2016 to follow up on an earlier case, in Palmyra.
Across those inspections OSHA issued 15 citation items: 9 serious and 6 other-than-serious.
OSHA proposed $29,400 in penalties and the amount has not been reduced.
Most often, OSHA cited 1910.147, lockout/tagout (3 items).
For context, across all staffing, cleaning and waste services employers the median penalty per cited inspection since 2015 is $2,217. Palmyra Borough DPW averages $29,400 over 1 cited inspection in that time.
New Jersey · latest 90 days of OSHA records
276employers cited
3 of them in the same industry
Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New Jersey
Checking a subcontractor, a client or your own company? Watch Palmyra Borough DPW and get notified the morning OSHA posts a new citation for it.
Watch this company93 Firth Lane, Palmyra, NJ 08065 · Facilities Support Services · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
93 Firth Lane, Palmyra, NJ 08065 · Facilities Support Services · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.36(g)(2) · Exit route design |
Serious | $2,800 | $2,800 | Nov 2, 2016 | Final |
| Citation 1, item 2 29 CFR 1910.147(c)(1) · Lockout/tagout |
Serious | $2,800 | $2,800 | Nov 2, 2016 | Final |
| Citation 1, item 3 29 CFR 1910.147(c)(5)(i) · Lockout/tagout |
Serious | $2,800 | $2,800 | Nov 2, 2016 | Final |
| Citation 1, item 4 29 CFR 1910.176(b) · Material storage and aisles |
Serious | $2,800 | $2,800 | Nov 2, 2016 | Final |
| Citation 1, item 5 29 CFR 1910.176(c) · Material storage and aisles |
Serious | $2,800 | $2,800 | Nov 2, 2016 | Final |
| Citation 1, item 6 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Serious | $2,800 | $2,800 | Nov 2, 2016 | Final |
| Citation 1, item 7 29 CFR 1910.212(b) · Machine guarding |
Serious | $2,800 | $2,800 | Nov 2, 2016 | Final |
| Citation 1, item 8 29 CFR 1910.304(f)(1)(iv) · Grounding and circuit protection |
Serious | $2,800 | $2,800 | Nov 2, 2016 | Final |
| Citation 1, item 9 29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods |
Serious | $2,800 | $2,800 | Nov 2, 2016 | Final |
| Citation 2, item 1 29 CFR 1910.37(b)(2) · Exit routes |
Other-than-serious | $700 | $700 | Nov 2, 2016 | Final |
| Citation 2, item 2 29 CFR 1910.145(c)(3) · Specifications for accident prevention signs and tags |
Other-than-serious | $700 | $700 | Nov 2, 2016 | Final |
| Citation 2, item 3 29 CFR 1910.147(c)(6)(i) · Lockout/tagout |
Other-than-serious | $700 | $700 | Nov 2, 2016 | Final |
| Citation 2, item 4 29 CFR 1910.157(c)(1) · Portable fire extinguishers |
Other-than-serious | $700 | $700 | Nov 2, 2016 | Final |
| Citation 2, item 5 29 CFR N.J.A.C. 12:100-7.5(A) |
Other-than-serious | $700 | $700 | Nov 2, 2016 | Final |
| Citation 2, item 6 29 CFR N.J.A.C. 12:100-7.8(A) (OPTION |
Other-than-serious | $700 | $700 | Nov 2, 2016 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.145(c)(3)
(3) Safety instruction signs. Safety instruction signs shall be used where there is a need for general instructions and suggestions relative to safety measures.
29 CFR 1910.147(c)(1)
(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.
29 CFR 1910.147(c)(5)(i)
(5) Protective materials and hardware. (i) Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware shall be provided by the employer for isolating, securing or blocking of machines or equipment from energy sources.
Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.