OSHA SearchOSHA records by employer

Panas Roofing & Siding LLC: OSHA inspections and violations

Green Bay, Wisconsin · Roofing Contractors · NAICS 238160

3inspections
13citation items
$17,710current penalties
May 15, 2026last inspection

OSHA has inspected Panas Roofing & Siding LLC 3 times in Wisconsin since 2013.

The latest one began on May 15, 2026, in Walworth; the case is still open.

Those inspections ended with 13 citation items: 10 serious and 3 other-than-serious.

Penalties were first proposed at $17,710 and still stand at $17,710.

Fall protection training in construction comes up most often in these citations: 3 items under 1926.503.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Panas Roofing & Siding LLC averages $7,455 (2 cited inspections).

Panas Roofing & Siding LLC: OSHA citation items per year, 2013 to 2026
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

218employers cited

47 of them in the same industry

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch Panas Roofing & Siding LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348940446 OPENED MAY 15, 2026Open

Inspection · Partial · Safety · 3 employees at the site · Open

434 Madison St., Walworth, WI 53184 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$4,965$4,965May 29, 2026Final
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$3,547$3,547May 29, 2026Final
Citation 2, item 1
29 CFR 1926.503(a)(1) · Fall protection training in construction
Other-than-serious$398$398May 29, 2026Final

Inspection 340829944 OPENED AUG 6, 2015Closed

Planned · Partial · Safety · 6 employees at the site · Closed Jul 17, 2019

310 Main Street, Delavan, WI 53115 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,800$2,800Dec 11, 2015Final
Citation 1, item 2
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$2,800$2,800Dec 11, 2015Final
Citation 2, item 1
29 CFR 1903.19(d)(1) · Proving cited hazards were fixed
Other-than-serious$400$400Feb 9, 2016Final

Inspection 339163065 OPENED JUL 2, 2013Closed

Planned · Partial · Safety · 4 employees at the site · Closed Sep 11, 2018

2000 Block Of Lone Grove Ave, Green Bay, WI 54303 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.403(b)(1)(i) · Electrical equipment on job sites
Serious$1,600$1,600Aug 13, 2013Final
Citation 1, item 1b
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$0$0Aug 13, 2013Final
Citation 1, item 1c
29 CFR 1926.405(a)(2)(ii)(j) · Job-site wiring
Serious$0$0Aug 13, 2013Final
Citation 1, item 2a
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$1,200$1,200Aug 13, 2013Final
Citation 1, item 2b
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$0$0Aug 13, 2013Final
Citation 1, item 2c
29 CFR 1926.1060(a)(1)(v) · Ladder and stairway training
Serious$0$0Aug 13, 2013Final
Citation 2, item 1
29 CFR 1926.503(a)(2)(viii) · Fall protection training in construction
Other-than-serious$0$0Aug 13, 2013Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.19 · Proving cited hazards were fixed

29 CFR 1903.19(d)(1)

(d) Abatement documentation. (1) The employer must submit to the Agency, along with the information on abatement certification required by paragraph (c)(3) of this section, documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.1060 · Ladder and stairway training

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other roofing contractors employers in Wisconsin

Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.