The inspection began on Sep 2, 2020 as a planned inspection, in Ocean Springs.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $10,988 and still stand at $10,988.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Pancho Gutierres averages $10,988 (1 cited inspection).

Pancho Gutierres: OSHA citation items per year, 2020 to 2020
Citation items per year, by inspection date.

Mississippi · latest 90 days of OSHA records

15employers cited

Get notified the morning OSHA posts each new citation in Mississippi: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Mississippi

Checking a subcontractor, a client or your own company? Watch Pancho Gutierres and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344911185 OPENED SEP 2, 2020Closed

Planned · Complete · Safety · 5 employees at the site · Closed Sep 26, 2025

104 Spanish Cove, Ocean Springs, MS 39564 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.304(d) · Woodworking tools
Serious$4,048$4,048Nov 2, 2020Final
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$4,048$4,048Nov 2, 2020Final
Citation 1, item 3
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$2,892$2,892Nov 2, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.304 · Woodworking tools

29 CFR 1926.304(d)

(d) Guarding. All portable, power-driven circular saws shall be equipped with guards above and below the base plate or shoe. The upper guard shall cover the saw to the depth of the teeth, except for the minimum arc required to permit the base to be tilted for bevel cuts. The lower guard shall cover the saw to the depth of the teeth, except for the minimum arc required to allow proper retraction and contact with the work. When the tool is withdrawn from the work, the lower guard shall automatically and instantly return to the covering position.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.503(a)(1)

(a) Training program. (1) The employer shall provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards.