OSHA SearchOSHA records by employer

Panetta Contracting and Masonry, Inc.: OSHA inspections and violations

Harrison, New York · All Other Specialty Trade Contractors · NAICS 238990

1inspections
3citation items
$3,300current penalties
May 26, 2016last inspection

Panetta Contracting and Masonry, Inc. has one OSHA inspection on record in New York.

OSHA opened it on May 26, 2016 as part of a related case, in Harrison.

From that inspection OSHA issued 3 citation items: 3 serious.

OSHA proposed $4,400 in penalties. After settlements and reviews the total is $3,300, down 25%.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Panetta Contracting and Masonry, Inc. averages $3,300 over 1 cited inspection in that time.

Panetta Contracting and Masonry, Inc.: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

361employers cited

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Panetta Contracting and Masonry, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341615318 OPENED MAY 26, 2016Closed

Unprogrammed related · Partial · Safety · 2 employees at the site · Closed Sep 14, 2016

92 Thatcher Avenue, Harrison, NY 10528 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.300(b)(2) · Tools—Hand and Power: general requirements
Serious$1,600$1,200Jul 18, 2016Final
Citation 1, item 2
29 CFR 1926.416(e)(1) · Electrical safety in construction
Serious$1,200$900Jul 18, 2016Final
Citation 1, item 3
29 CFR 1926.1052(c)(1) · Stairways in construction
Serious$1,600$1,200Jul 18, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)

(1) Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with:

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.300(b)(2)

(2) Belts, gears, shafts, pulleys, sprockets, spindles, drums, fly wheels, chains, or other reciprocating, rotating or moving parts of equipment shall be guarded if such parts are exposed to contact by employees or otherwise create a hazard. Guarding shall meet the requirements as set forth in American National Standards Institute, B15.1-1953 (R1958), Safety Code for Mechanical Power-Transmission Apparatus.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.416(e)(1)

(e) Cords and cables. (1) Worn or frayed electric cords or cables shall not be used.

Other all other specialty trade contractors employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.