OSHA SearchOSHA records by employer

Pantigas Construction: OSHA inspections and violations

Pigeon Forge, Tennessee · Framing Contractors · NAICS 238130

1inspections
6citation items
$10,800current penalties
Jan 24, 2025last inspection

Pantigas Construction has one OSHA inspection on record in Tennessee.

OSHA opened it on Jan 24, 2025 on a referral, in Pigeon Forge.

From that inspection OSHA issued 6 citation items: 6 serious.

OSHA proposed $10,800 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (5 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Pantigas Construction averages $10,800 over 1 cited inspection in that time.

Pantigas Construction: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

353employers cited

19 of them in the same industry

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch Pantigas Construction and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347997777 OPENED JAN 24, 2025Closed

Referral · Partial · Safety · 4 employees at the site · Closed Feb 3, 2026

835 Osprey Way, Pigeon Forge, TN 37868 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(a)(1) · Scaffolds, general requirements
Serious$1,200$1,200Mar 5, 2025Final
Citation 1, item 1b
29 CFR 1926.451(f)(16) · Scaffolds, general requirements
Serious$0$0Mar 5, 2025Final
Citation 1, item 2
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$800$800Mar 5, 2025Final
Citation 1, item 3
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$800$800Mar 5, 2025Final
Citation 1, item 4
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$4,000$4,000Mar 5, 2025Final
Citation 1, item 5
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$4,000$4,000Mar 5, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(1)

(a) Capacity. (1) Except as provided in paragraphs (a)(2), (a)(3), (a)(4), (a)(5) and (g) of this section, each scaffold and scaffold component shall be capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it.

29 CFR 1926.451(a)(6)

(6) Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. Non-mandatory appendix A to this subpart contains examples of criteria that will enable an employer to comply with paragraph (a) of this section.

29 CFR 1926.451(b)(2)

(2) Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide.

29 CFR 1926.501 · Fall protection in construction

Other framing contractors employers in Tennessee

Alert subscribers get notified of each newly cited employer in Tennessee the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.