OSHA SearchOSHA records by employer

Par Builders II Inc: OSHA inspections and violations

St. Petersburg, Florida · Commercial and Institutional Building Construction · NAICS 236220

7inspections
17citation items
$12,100current penalties
Feb 7, 2025last inspection

Par Builders II Inc has 7 OSHA inspections on record in Florida, the first in 1992.

OSHA's last visit started on Feb 7, 2025 as a planned inspection, in Saint Augustine.

Across those inspections OSHA issued 17 citation items: 14 serious and 3 other-than-serious.

OSHA proposed $18,445 in penalties. After settlements and reviews the total is $12,100, down 34%.

Most often, OSHA cited 1926.405, job-site wiring (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Par Builders II Inc averages $7,000 over 1 cited inspection in that time.

Par Builders II Inc: OSHA citation items per year, 1992 to 2025
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

326employers cited

8 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Par Builders II Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348028978 OPENED FEB 7, 2025Closed

Planned · Complete · Safety · 1 employee at the site · Closed May 23, 2025

131 Mccoy Way, Saint Augustine, FL 32095 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$5,675$3,300Apr 25, 2025Final
Citation 1, item 2
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$6,620$3,700Apr 25, 2025Final

Inspection 341420990 OPENED APR 22, 2016Closed

Planned · No inspection · Safety · 1 employee at the site · Closed Apr 29, 2016

1089 Atlantic Blvd, Atlantic Beach, FL 32233 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 310758628 OPENED APR 17, 2007Closed

Planned · Complete · Safety · 1 employee at the site · Closed Jun 15, 2007

11610 Countryway Blvd, Tampa, FL 33611 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$450$338Jun 6, 2007Closed
Citation 1, item 2
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$750$562Jun 6, 2007Closed
Citation 1, item 3
29 CFR 1926.501(b)(14) · Fall protection in construction
Serious$750$562Jun 6, 2007Closed
Citation 1, item 4
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$750$562Jun 6, 2007Closed
Citation 1, item 5
29 CFR 1926.1052(b)(1) · Stairways in construction
Serious$750$562Jun 6, 2007Closed
Citation 1, item 6
29 CFR 1926.1052(c)(1) · Stairways in construction
Serious$750$562Jun 6, 2007Closed

Inspection 309270031 OPENED JUL 25, 2005Closed

Planned · Partial · Safety · 1 employee at the site · Closed Aug 1, 2005

2699 Roosevelt Blvd., Largo, FL 33760 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 307644880 OPENED APR 21, 2004Closed

Unprogrammed related · Complete · Safety · 1 employee at the site · Closed Apr 23, 2004

8915 W. Cortez Road, Bradenton, FL 34210 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 304516867 OPENED MAY 9, 2001Closed

Referral · Complete · Safety · 1 employee at the site · Closed Jun 1, 2001

2525 E. Michigan Street, Orlando, FL 32806 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(a)(2)(iic) · Job-site wiring
Serious$225$225May 23, 2001Closed
Citation 1, item 2a
29 CFR 1926.405(a)(2)(iii) · Job-site wiring
Serious$225$225May 23, 2001Closed
Citation 1, item 2b
29 CFR 1926.405(j)(2)(ii) · Job-site wiring
Serious$0$0May 23, 2001Closed
Citation 1, item 3
29 CFR 1926.651(j)(2) · Excavations
Serious$750$750May 23, 2001Closed
Citation 1, item 4a
29 CFR 1926.652(a)(1) · Trench protection
Serious$750$750May 23, 2001Closed
Citation 1, item 4b
29 CFR 1926.651(k)(1) · Excavations
Serious$0$0May 23, 2001Closed
Citation 2, item 1
29 CFR 1926.50(d)(1) · Medical services and first aid
Other-than-serious$0$0May 23, 2001Closed
Citation 2, item 2
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Other-than-serious$0$0May 23, 2001Closed

Inspection 106495989 OPENED FEB 6, 1992Closed

Unprogrammed related · Partial · Health · 1 employee at the site · Closed May 4, 1992

3135 1st Ave. North, St. Petersburg, FL 33730 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.59(e)(1) · Hazard communication
Other-than-serious$0$0Apr 23, 1992Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(b)(1)

(1) Except during stairway construction, foot traffic is prohibited on stairways with pan stairs where the treads and/or landings are to be filled in with concrete or other material at a later date, unless the stairs are temporarily fitted with wood or other solid material at least to the top edge of each pan. Such temporary treads and landings shall be replaced when worn below the level of the top edge of the pan.

29 CFR 1926.1052(c)(1)

(1) Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with:

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.50 · Medical services and first aid

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.59 · Hazard communication

29 CFR 1926.651 · Excavations

29 CFR 1926.652 · Trench protection

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

Other commercial and institutional building construction employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.