Inspection 342115763 OPENED FEB 15, 2017Closed
2938 E Main St, Parish, NY 13131 · Other General Government Support · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 1989, OSHA inspectors have visited Parish Vill Mun BLDG in New York 13 times.
The most recent inspection opened on Feb 15, 2017 to follow up on an earlier case, in Parish.
In all, OSHA issued 17 citation items: 13 serious and 4 other-than-serious.
No penalty came with these citations.
The rule cited most here is 1910.37 (exit routes), 6 times.
Among public administration employers, the typical cited inspection since 2015 ends with a $0 penalty. Parish Vill Mun BLDG averages $0 across 1 cited inspection.
New York · latest 90 days of OSHA records
362employers cited
7 of them in the same industry
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch Parish Vill Mun BLDG and get notified the morning OSHA posts a new citation for it.
Watch this company2938 E Main St, Parish, NY 13131 · Other General Government Support · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2938 E Main St, Parish, NY 13131 · Other General Government Support · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.37(a)(4) · Exit routes |
Serious | $0 | $0 | Jan 18, 2017 | Final |
| Citation 1, item 2 29 CFR 1910.37(b)(2) · Exit routes |
Serious | $0 | $0 | Jan 18, 2017 | Final |
| Citation 1, item 3 29 CFR 1910.37(b)(5) · Exit routes |
Serious | $0 | $0 | Jan 18, 2017 | Final |
| Citation 1, item 4 29 CFR 1910.305(b)(2)(i) · Electrical wiring methods |
Serious | $0 | $0 | Jan 18, 2017 | Final |
| Citation 2, item 1 29 CFR 12 NYCRR PART 801.29(A) |
Other-than-serious | $0 | $0 | Jan 18, 2017 | Final |
2938 East Main St, Parish, NY 13131 · Other General Government Support · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2938 East Main St, Parish, NY 13131 · Other General Government Support · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 8000006 F03 |
Serious | $0 | $0 | Jul 17, 2013 | Closed |
| Citation 1, item 2 29 CFR 8000006 H01 |
Serious | $0 | $0 | Jul 17, 2013 | Closed |
| Citation 1, item 3 29 CFR 8010004 A |
Serious | $0 | $0 | Jul 17, 2013 | Closed |
2938 East Main St, Parish, NY 13131 · Other General Government Support · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2938 East Main St, Parish, NY 13131 · Other General Government Support · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.37(a)(3) · Exit routes |
Serious | $0 | $0 | Jul 9, 2008 | Closed |
| Citation 1, item 2 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Serious | $0 | $0 | Jul 9, 2008 | Closed |
| Citation 1, item 3 29 CFR 1910.305(b)(2)(i) · Electrical wiring methods |
Serious | $0 | $0 | Jul 9, 2008 | Closed |
| Citation 2, item 1 29 CFR 1910.37(b)(6) · Exit routes |
Other-than-serious | $0 | $0 | Jul 9, 2008 | Closed |
2938 East Main St, Parish, NY 13131 · Other General Government Support · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2938 East Main St, Parish, NY 13131 · Other General Government Support · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2938 East Main St, Parish, NY 13131 · Other General Government Support · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2938 East Main St, Parish, NY 13131 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2938 East Main St, Parish, NY 13131 · Other General Government Support · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.36(b)(1) · Exit route design |
Serious | $0 | $0 | Jun 14, 2002 | Closed |
| Citation 1, item 2 29 CFR 1910.37(j) · Exit routes |
Serious | $0 | $0 | Jun 14, 2002 | Closed |
| Citation 1, item 3 29 CFR 1910.304(f)(7)(iii) · Grounding and circuit protection |
Serious | $0 | $0 | Jun 14, 2002 | Closed |
| Citation 2, item 1 29 CFR 1910.36(b)(6) · Exit route design |
Other-than-serious | $0 | $0 | Jun 14, 2002 | Closed |
2938 East Main St, Parish, NY 13131 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2938 East Main St, Parish, NY 13131 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Nov 14, 1989 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.303(b)(2)
(2) Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.
29 CFR 1910.305(b)(2)(i)
(2) Covers and canopies. (i) All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.
29 CFR 1910.305(g)(1)(iii)
(iii) If used as permitted in paragraphs (g)(1)(ii)(C), (g)(1)(ii)(G), or (g)(1)(ii)(I) of this section, the flexible cord shall be equipped with an attachment plug and shall be energized from an approved receptacle outlet.
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.