OSHA SearchOSHA records by employer

Park Motel: OSHA inspections and violations

Winnemucca, Nevada · Hotels (except Casino Hotels) and Motels · NAICS 721110

1inspections
6citation items
$900current penalties
Mar 7, 2016last inspection

Park Motel has one OSHA inspection on record in Nevada.

OSHA opened it on Mar 7, 2016 after a complaint, in Winnemucca.

From that inspection OSHA issued 6 citation items: 2 serious and 4 other-than-serious.

OSHA proposed $1,800 in penalties. After settlements and reviews the total is $900, down 50%.

Most often, OSHA cited 1910.305, electrical wiring methods (2 items).

For context, across all hotel and restaurant employers the median penalty per cited inspection since 2015 is $1,350. Park Motel averages $900 over 1 cited inspection in that time.

Park Motel: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Nevada · latest 90 days of OSHA records

116employers cited

16 of them in the same industry

Get notified the morning OSHA posts each new citation in Nevada: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Nevada

Checking a subcontractor, a client or your own company? Watch Park Motel and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341313260 OPENED MAR 7, 2016Closed

Complaint · Partial · Safety · 3 employees at the site · Closed Jun 20, 2016

740 W. Winnemucca Boulevard, Winnemucca, NV 89445 · Hotels (except Casino Hotels) and Motels · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$600$300Apr 15, 2016Final
Citation 1, item 2
29 CFR 1910.305(d)(2) · Electrical wiring methods
Serious$1,200$600Apr 15, 2016Final
Citation 2, item 1
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Apr 15, 2016Final
Citation 2, item 2
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Apr 15, 2016Final
Citation 2, item 3
29 CFR 1910.304(b)(4)(ii)(c) · Grounding and circuit protection
Other-than-serious$0$0Apr 15, 2016Final
Citation 2, item 4
29 CFR 1910.305(j)(1)(i) · Electrical wiring methods
Other-than-serious$0$0Apr 15, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(2)

(2) Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.

29 CFR 1910.303(f)(2)

(2) Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.304(b)(4)(ii)(c)

(C) Where connected to a branch circuit supplying two or more receptacles or outlets, receptacle ratings shall conform to the values listed in Table S-5; or, where larger than 50 amperes, the receptacle rating may not be less than the branch-circuit rating. However, receptacles of cord- and plug-connected arc welders may have ampere ratings not less than the minimum branch-circuit conductor ampacity.

29 CFR 1910.305 · Electrical wiring methods

Other hotels (except casino hotels) and motels employers in Nevada

Alert subscribers get notified of each newly cited employer in Nevada the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.